Error description

  • URLMappings may interfere with Friendly Name resolution so that
    a URLMapping is parsed but portal sends a redirect to an
    encoded URL to the same page instead of serving the URLMapping
    request
    directly.
    So a browser request to wps/myportal/URLMAPPING/ is incorrectly
    redirected to the same page with encoded URL:
    wps/myportal/!ut/p/...
    
    Traces for com.ibm.wps.engine.*=all show the following message,
    although no Friendly Name is present for the current page and
    URL:
    WPActionPhase 2 com.ibm.wps.engine.phases.WPActionPhase
    getFriendlyRedirectURL(req, resp, state, manager) A redirect is
    required, because the URL start with the friendly path [/<URL
    Mapping>] which does not match the path of [[ObjectIDImpl
    '6_...]].
    WPActionPhase < com.ibm.wps.engine.phases.WPActionPhase
    getFriendlyRedirectURL(req, resp, state, manager) RETURN
    /wps/myportal/!ut/p/c5/04_SB8K8...
    

Local fix

  • NA
    

Problem summary

  • URLMappings may interfere with Friendly Name resolution so
    that a URLMapping is parsed but portal sends a redirect to an
    encoded URL to the same page instead of serving the URLMapping
    request directly.
    So a browser request to wps/myportal/URLMAPPING/ is
    incorrectly redirected to the same page with encoded URL:
       wps/myportal/!ut/p/...
    

Problem conclusion

  • The URL Mapping and FriendlyName resolution is corrected to not
    issue the redirect.
    
    Manual Steps:
       None
    
    Failing Module(s):
       Engine: URL Generation
    
    Affected Users:
       All users
    
    Version Information:
        Portal Version(s): 6.1.0.1
         Pre-Requisite(s): PK97514
          Co-Requisite(s): ---
    
        Portal Version(s): 6.1.0.2
         Pre-Requisite(s): PK97514
          Co-Requisite(s): ---
    
        Portal Version(s): 6.1.0.3
         Pre-Requisite(s):
          Co-Requisite(s): ---
    
    Platform Specific:
       This fix applies to all platforms.
    
    A fix is available from Fix Central:
    
    http://www.ibm.com/eserver/support/fixes/fixcentral/swgquickorde
    r?apar=PK99273&productid=WebSphere%20Portal&brandid=5
    
    You may need to type or paste the complete address into your Web
    browser.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK99273

  • Reported component name

    WEBSPHERE PORTA

  • Reported component ID

    5724E7600

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-10-22

  • Closed date

    2009-11-09

  • Last modified date

    2010-03-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE PORTA

  • Fixed component ID

    5724E7600

Applicable component levels

  • R61A PSY

       UP

  • R61B PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSHRKX","label":"WebSphere Portal"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB31","label":"WCE Watson Marketing and Commerce"}}]

Document Information

Modified date:
21 December 2021