A fix is available
APAR status
Closed as program error.
Error description
ABENDS0C4 in IPIGQDMP near x'450' during monitor reporting. Monitor out-of-sequence records caused negative elapsed times to be calculated, confusing IMS PA. S0C4 caused by AMODE error in ESTAE exit while reporting problem. This issue is forward fit to V420 in V420 APAR PM02602.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Performance Analyzer V4.1 * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 in IPIGQDMP during monitor * * reporting. * **************************************************************** * RECOMMENDATION: * **************************************************************** Monitor out-of-sequence records caused negative elapsed times to be calculated, confusing IMS PA. 0C4 caused by AMODE error in ESTAE exit while reporting problem.
Problem conclusion
Discard queue entries with negative times, fix AMODE in IPIGQDMP
Temporary fix
Comments
APAR Information
APAR number
PK99192
Reported component name
IMS PERF ANALYZ
Reported component ID
5655E1500
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-10-21
Closed date
2009-12-15
Last modified date
2010-01-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK52870
Modules/Macros
IPIAQR11 IPIGQDMP
Fix information
Fixed component name
IMS PERF ANALYZ
Fixed component ID
5655E1500
Applicable component levels
R410 PSY UK52870
UP09/12/21 P F912
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Performance Analyzer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410"}]
Document Information
Modified date:
14 December 2020