A fix is available
APAR status
Closed as program error.
Error description
ABENDS0C4 in IPI4PROC when flushing queue elements for high water mark (HWM) processing to add program-switch responses. Originating Transactions can be flushed at high-water mark (HWS) processing when trying to add program-switch response records and link them to the corresponding Originating Transactions. . ABEND occurs at x'15b2' into MOD IPIIPROC and LMOD is IPI4PROC . Another occurrence of this issue was reported at offset x'046e' with R5 being invalid (D3F5F1F0), therefore any abend0c4 in this routine we recommend installing the PTF for this issue, as abend locations may vary.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Performance Analyzer V4.1 * **************************************************************** * PROBLEM DESCRIPTION: Abend0C4 in IPIIPROC module in IPI4PROC * * load module when flushing queue * * elements for high water mark (HWM) * * processing to add program-switch * * responses. * **************************************************************** * RECOMMENDATION: * **************************************************************** Originating Transactions can be flushed at high-water mark (HWS) processing when trying to add program-switch response records and link them to the corresponding Originating Transactions.
Problem conclusion
Change code to ensure that the current transaction pointer is set to the top-level transaction in the transit-set when adding a program-switch response, before checking eligibility of the current transaction for flushing, so that the program-switch response has a valid anchor.
Temporary fix
Comments
APAR Information
APAR number
PK98344
Reported component name
IMS PERF ANALYZ
Reported component ID
5655E1500
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-10-09
Closed date
2009-10-15
Last modified date
2009-12-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK51063
Modules/Macros
IPIIPROC IPISLOGT IPISTS00
Fix information
Fixed component name
IMS PERF ANALYZ
Fixed component ID
5655E1500
Applicable component levels
R410 PSY UK51063
UP09/10/20 P F910
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Performance Analyzer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"","label":""}}]