A fix is available
APAR status
Closed as program error.
Error description
Customer reported that OmPE shows different values for some parameters from DSNZPARM system parameter setting values, e.g.: ------------------------------------------------------- PARAMETER SETTING BATCH REPORT OmPE Classic ------------------------------------------------------- ACCUMACC NO 0 (no field) CACHERAC 32768 32768 0 HOPAUTH BOTH PKGOWNER YES MAXRBLK 10192 10420224 10176K RGFDEFLT ACCEPT ACCEPT REJECT TRACTBL 16 16 64K ------------------------------------------------------- where OmPE Classic - ZPSYS: DSNZPARM INFORMATION panel (fast path R.H.*)
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - Classic Interface * * - CUA Interface * **************************************************************** * PROBLEM DESCRIPTION: ZPARM values are wrong for * * RGFDEFLT and CACHERAC * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: ZPARM values are wrong for RGFDEFLT and CACHERAC PROBLEM CONCLUSION: Correctly display RGFDEFLT field on panel ZPDDC and CACHERAC field on ZPSTG
Problem conclusion
Correctly display RGFDEFLT field on panel ZPDDC and CACHERAC field on ZPSTG
Temporary fix
Comments
APAR Information
APAR number
PK97461
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-09-30
Closed date
2009-11-02
Last modified date
2009-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK51590 UK51592
Modules/Macros
KD2VSTG7 KD29STG7 KO2APCBA KO2APCBS KO2APCB2 KO2CBUFB KO2CSYSA KO2CSYSS KO2CSYS2 KO2CZPMB KO2OTRCB KO2OZPMB KO2PSTGH
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
02 December 2009