Error description

  • This solution is to generate additional diagnostics data which
    will help to analyze SVC dumps with the titles
    having the keywords 'INCORRECT RA', 'INCORRECT DPM0', 'HIGH CPU'
    in their titles. These dumps are produced by PE Server subtask
    when a corresponding problem comes up.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - PE Server subtask                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: Internal data server trace enhancement  *
    *                      for PE Server subtask                   *
    *                                                              *
    *                      For V420: FFit of V410 APAR PK87487     *
    *                      When the OMEGAMON Collector PE Server   *
    *                      subtask initializes the function        *
    *                      Snapshot History, an already existing   *
    *                      Snapshot History data set is read to    *
    *                      build the table of contents. Reading a  *
    *                      corrupted data set can cause an ABEND   *
    *                      S0C4-004 in module DGOVHM00 at offset   *
    *                      0000F8D0 or others. After Snapshot      *
    *                      History abends, the PE Server subtask   *
    *                      tries to restart the Snapshot History   *
    *                      Manager subtask which fails again       *
    *                      because it tries to read the same       *
    *                      corrupted data set.                     *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    This solution is to generate additional diagnostic data which
    will help to analyze SVC dumps with the titles containing the
    keywords 'INCORRECT RA', 'INCORRECT DPM0', 'HIGH CPU' in their
    titles. These dumps are produced by PE Server subtask when a
    corresponding problem comes up.
    
    For V420: FFit of V410 APAR PK87487
    During initialization of the Snapshot History Manager an already
    existing Snapshot History data set is read to build the table of
    contents. When corrupted data are read, the processing of the
    data can cause an ABEND S0C4 in load module DGOVHM00. The PE
    Server subtask tries to recover once and therefore restarts the
    Snapshot History Manager. The same corrupted data are read again
    and cause the same ABEND S0C4.
    
    KEYWORDS:
    INCORRECT-RA INCORRECT-DPM0 HIGH-CPU-DGOVHM00
    INTERNAL-DATA-SERVER-TRACE
    ABEND S0C4-004 DGOVHM00 SNAPSHOT HISTORY
    

Problem conclusion

  • This solution is to generate additional diagnostic data which
    will help to analyze SVC dumps with the titles containing the
    keywords 'INCORRECT RA', 'INCORRECT DPM0', 'HIGH CPU' in their
    titles. These dumps are produced by PE Server subtask when a
    corresponding problem comes up.
    
    For V420: FFit of V410 APAR PK87487
    When the Snapshot History data set is read, the data are checked
    for consistency before they are processed to build the table of
    contents. When inconsistencies are detected, the Snapshot
    History data set is renamed and a new Snapshot History data set
    is allocated to continue the collection of Snapshot History
    data.
    
    KEYWORDS:
    INCORRECT-RA INCORRECT-DPM0 HIGH-CPU-DGOVHM00
    INTERNAL-DATA-SERVER-TRACE
    ABEND S0C4-004 DGOVHM00 SNAPSHOT HISTORY
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK97285

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-09-28

  • Closed date

    2009-10-13

  • Last modified date

    2009-11-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK50945 UK50946

Modules/Macros

  • DGOVDB2C DGOVHMDR DGOVHMS1 DGOVHMTC DGOVMSTR
    DGOVSADJ DGOVSCO1 DGOVWDOG FPE@DB2I FPEVDB2I
    

Publications Referenced
GC18998002GC19250600   

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK50945

       UP09/10/14 P F910

  • R420 PSY UK50946

       UP09/10/14 P F910

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
04 November 2009