APAR status
Closed as program error.
Error description
The following exceptions are found in the logs when running large XMLAccess script on a node that is currently accessed: Caused by: java.lang.IllegalStateException: Timeout while waiting for read locks to be released. Write lock was not acquired. Those exceptions are accompanied by 5 sec wait cycles of the XMLAccess process. The APAR fixes and issue with xmlaccess processing of the request parameter synchronous-cache-update (default=false). Additionally, two new configuration parameters are introduced for the ThreadsafeContentModel class that issues the IllegalStateException: WP ConfigService: content.topology.writelock.timeout=<milliseconds> (default=25000) - This setting controls the maximum wait time to optain a writable model before issuing a timeout warning. content.topology.writelock.dump=true|false (default=false) -> This setting controls if a java core dump should be written in case of a timeout event for debugging. Use the WAS admin console - Resource Environment Providers - to add or change the settings and restart the Portal Server afterwards. Observed stacktrace: com.ibm.wps.services.events.ReflectHandler invoke() EJPFD0021E: Error while invoking an event handler. java.lang.reflect.InvocationTargetException Caused by: java.lang.IllegalStateException: Timeout while waiting for read locks to be released. Write lock was not acquired. at com.ibm.wps.model.content.impl.ThreadsafeContentModelImpl.writeB gin(ThreadsafeContentModelImpl.java:131) at com.ibm.wps.model.content.impl.ContentModelImpl.invalidate(Conte tModelImpl.java:997)
Local fix
A possible workaround is to use the following two request attributes for xmlaccess: transaction-level="none" synchronous-cache-update="true"
Problem summary
The following exceptions are found in the logs when running large XMLAccess script on a node that is currently accessed: Caused by: java.lang.IllegalStateException: Timeout while waiting for read locks to be released. Write lock was not acquired. Those exceptions are accompanied by 5 sec wait cycles of the XMLAccess process.
Problem conclusion
The APAR fixes and issue with xmlaccess processing of the request parameter synchronous-cache-update (default=false). Additionally, two new configuration parameters are introduced for the ThreadsafeContentModel class that issues the IllegalStateException: WP ConfigService: content.topology.writelock.timeout=<milliseconds> (default=25000) content.topology.writelock.dump=true|false (default=false) Use the WAS admin console - Resource Environment Providers - to add or change the settings and restart the Portal Server afterwards. Manual Steps: None Failing Module(s): XML Access Affected Users: All Users Version Information: Portal Version(s): 6.1.0.1 Pre-Requisite(s): PK95161 Co-Requisite(s): --- Portal Version(s): 6.1.0.2 Pre-Requisite(s): PK95161 Co-Requisite(s): --- Platform Specific: This fix applies to all platforms. A fix is available from Fix Central: http://www.ibm.com/eserver/support/fixes/fixcentral/swgquickorde ?apar=PK96805&productid=WebSphere%20Portal&brandid=5 You may need to type or paste the complete address into your Web browser.
Temporary fix
Comments
APAR Information
APAR number
PK96805
Reported component name
WEBSPHERE PORTA
Reported component ID
5724E7600
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-09-22
Closed date
2009-10-22
Last modified date
2009-10-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE PORTA
Fixed component ID
5724E7600
Applicable component levels
R61A PSY
UP
R61B PSY
UP