Error description
-
This error occurs after VTOC Index was extended on an HDS DASD Volume. When Space Monitor runs against the DASD volume, IOS000I message appears. And Space Monitor sets all zero in FREE SPACE ON VOLUME section in "TOTAL DASD UTILIZATION BY VOLUME/DEVICE-TYPE REPORT".
Local fix
-
N/A
Problem summary
-
**************************************************************** * USERS AFFECTED: IBM IMS High Performance Pointer Checker for * * z/OS Version 2 Release 2 (FMID=HPC2220) * * users who use Space Monitor (SPMN). * **************************************************************** * PROBLEM DESCRIPTION: Space Monitor reports zero as free * * space incorrectly after VTOC Index * * extended. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This error occurs after VTOC Index was extended on an HDS DASD Volume. SPMN issues OBTAIN macro with an absolute disk address to search the FORMAT-1 DSCB of VTOC index data set, reads VTOC Index, and gets free space information. However, SPMN encounters OBTAIN macro failure, because the FORMAT-1 DSCB of VTOC index data set is not in the specified address in case of HDS DASD. This is why MSGIOS000I is issued incorrectly and SPMN sets all zero in FREE SPACE ON VOLUME section in "TOTAL DASD UTILIZATION BY VOLUME/DEVICE-TYPE REPORT".
Problem conclusion
-
The following modules are modified to issue OBTAIN MACRO with VTOC data set name. FABKCOLL,FABKGRUP,FABKMGTB
Temporary fix
Comments
APAR Information
-
APAR number
PK96498
-
Reported component name
IMS POINTER CHE
-
Reported component ID
5655E0900
-
Reported release
220
-
Status
CLOSED PER
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2009-09-17
-
Closed date
2009-10-05
-
Last modified date
2009-11-04
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
UK50763
Modules/Macros
-
FABKCOLL FABKGRUP FABKMGTB
Fix information
-
Fixed component name
IMS POINTER CHE
-
Fixed component ID
5655E0900
Applicable component levels
-
R220 PSY UK50763
UP09/10/07 P F910
Fix is available
-
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.