A fix is available
APAR status
Closed as new function.
Error description
Change QCF initialization to not just wait for SCI to come up. Instead a message will be issued and QCF initialization will continue. On SCI start it will connect and QCF services will be active. If SCI does not start, no QCF functions will be available (panels, batch jobs, etc.).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All QCF V3.1 users * **************************************************************** * PROBLEM DESCRIPTION: If the SCI task has not been started wh * * en IMS is restarted, QCF initialization * * just wait for SCI to come up. But depe * * ndent regions started in this state wil * * l not be initialized and consequently n * * ot be able to process transactions. * **************************************************************** * RECOMMENDATION: * **************************************************************** If the SCI task has not been started when IMS is restarted, QCF initialization wait for SCI to come up and hung the MPP region.
Problem conclusion
Temporary fix
Comments
Now the QCF initialization was changed to be as that. When we st art IMS, if no SCI is up, QCF would auto-start specified SCI PRO C; if nothing specified or SCI start fail, QCF would wait till S CI available then do the SCI register. For the first 30 minutes, QCF would try to register at a 6 sec interval (same as the old logic); then after 30 min, QCF would try to register every 10 mi nutes. And the IMS hung problem is solved, the user should be ab le to run MPP when IMS is successfully started, QCF waiting for the SCI should not be an impact.
APAR Information
APAR number
PK95888
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
310
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-09-10
Closed date
2010-07-06
Last modified date
2010-08-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK58602
Modules/Macros
IQC##### IQCBPECF IQCCCPRM IQCCIN0A IQCCIN0B IQCCIN0X IQCCIN08 IQCCIN09 IQCCIN1A IQCCIN1B IQCCIN1X IQCCIN18 IQCCIN19 IQCCQAB IQCCSLSI IQCC1ENU IQCIMSII IQCSCI IQCSIN10
| SC18987503 |
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R310 PSY UK58602
UP10/07/09 P F007
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]