A fix is available
APAR status
Closed as program error.
Error description
- FUN2221F Syntax error using the batch utilities to convert from 1.2 to 2.1 - Message CEX5015E and CEX5016E when trying tried to format IMS V11 IMS Connect recorder trace records KEYWORDS: IMSV11TGT/K - An 0C6 can occur in CEXTECL if the storage returned via getmain has not been cleared by Z/OS. Preceding the abend message CEX5035I CONTROL HAS BEEN PASSED TO THE SECOND HWSTECL0 is issued. - If the CEX journal manager attempts to submit an archive job to JES via the internal reader while JES is not available, the internal reader process will hang and prevent CEX from journaling event records until JES has been restarted. This is likely to result in the IMS Connect region entering a wait state because all of the event recording buffers are full. - Event record macros for events 48 - 51 are missing the TCBIB control block definition - When IMS Connect Extensions is performing RACF User verification in a Z/OS 1.10 environment, an ABEND878 can occur due to a change in processing of the MSGRTRN=YES request. Message ICH70001I is now returned for a successful verification of the User where previously they were not. This results in CEX not freeing the unexpected message returned storage.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Connect Extensions V2.2 * **************************************************************** * PROBLEM DESCRIPTION: Rollup maintenance for CEX 220 * **************************************************************** * RECOMMENDATION: * **************************************************************** Rollup Maintenance for CEX 220. The following items are fixed: 1. FUN2221F Syntax error using the batch utilities to convert from 1.2 to 2.1 2. Message CEX5015E and CEX5016E when trying to format IMS V11 IMS Connect recorder trace records 3. An 0C6 can occur in CEXTECL if the storage returned via getmain has not been cleared by Z/OS. Preceeding the abend message CEX5035I CONTROL HAS BEEN PASSED TO THE SECOND HWSTECL0 is issued. 4. If the CEX journal manager attempts to submit an archive job to JES via the internal reader while JES is not available, the internal reader process will hang and prevent CEX from journaling event records until JES has been restarted. This is likely to result in the IMS Connect region entering a wait state because all of the event recording buffers are full. 5. Event record macros for events 48 - 51 are missing the TCBIB control block definition 6. When IMS Connect Extensions is performing RACF User verification in a Z/OS 1.10 environment, an abend S878 can occur due to a change in processing of the MSGRTRN=YES request. Message ICH70001I is now returned for a successful verification of the User where previously they were not. This results in CEX not freeing the unexpected message returned storage.
Problem conclusion
1. Changed the batch utilities to properly recognize unpopulated fields in the source repository and format the receiving repository with default values 2. Corrected the recorder trace formatting utilities to recognize and format the AX, AR, and AE recorder trace records for the XML adapter 3. Ensure any storage returned is cleared before using the storage. 4. This APAR changes the CEX Journal Manager component to submit the archive job using an asynchronous process that does not cause the journal manager task to wait for the archive jobstep submission. 5. Added the TCPIB control block definition to the event record macros 6. A change has been made to check for any returned messages and free the message storage as required
Temporary fix
Comments
APAR Information
APAR number
PK93875
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-08-13
Closed date
2009-11-19
Last modified date
2010-11-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK52132
Modules/Macros
CEX@PRIM CEXBDDSG CEXCONSS CEXCR48 CEXCR49 CEXCR50 CEXCR51 CEXDFN1 CEXEVTPR CEXEVT01 CEXEXRTR CEXMAIN CEXMAPI CEXMSGT CEXRCDPR CEXRCDUT CEXR101 CEXR161 CEXR162 CEXSALUT CEXSVC01 CEXTECL CEXTEOT CEXTPLST CEXVUSER
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R220 PSY UK52132
UP09/11/24 P F911
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]
Document Information
Modified date: