Error description

  • Dump Title: OMEGAMON II FOR DB2: COMPID=5655OPE00, JOB=CANSO2  ,
    LMOD=KO2DMGRB#L, CSECT=O2HSVP  , OFFSET=000DF0
    ABEND0C3 KO2HSVPB+DEC (at PK89128 level) issued intentionally
    when a loop was detected.  For this SVC DUMP, the LOOP was
    in CSECT KO2DXS2A (at PK91678 level) offsets 8F0 to ABA. The
    loop occurred because Omegamon failed to check for a zero
    length HEADER SECTION, using a length of x'0000' to advance to
    the next HEADER SECTION.  This can also happen in CSECTs
    KO2DDSBx and KO2DXS1x as well.  Also seen was message
    KO2O1421E NEAR-TERM HISTORY DATA COLLECTOR - WORKLOAD DANALYZE
              HAD LOOPED MORE THAN TEN TIMES. TERMINATING (SERVLOOP)
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   The component that transfers DB2         *
    *                     monitoring data collected by the         *
    *                     OMEGAMON collector to the TEMA           *
    ****************************************************************
    * PROBLEM DESCRIPTION: NTH Historical collector non-responsive *
    *                      to operator commands.                   *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF
    *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    Unexpected values in processed data causing looping condition.
    
    PROBLEM CONCLUSION:
    Code updated to check for unexpected values and handle
    correctly.
    

Problem conclusion

  • Code updated to check for unexpected values and handle
    correctly.
    
    KEYWORDS : NTH HISTORICAL COLLECTOR OPERATOR COMMANDS
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK93629

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-08-11

  • Closed date

    2009-10-29

  • Last modified date

    2010-07-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • KO2DDSBA KO2DDSBS KO2DDSB2 KO2DXS1A KO2DXS1S
    KO2DXS12 KO2DXS2A KO2DXS2S KO2DXS22
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R420 PSY UK51519

       UP09/11/05 P F911

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]