Error description
PK93393 is a forward fit of R410 Omegamon APAR PK83037. When the OMPE server is configured with AUTODETECT = YES and attaching to a data sharing group, the OMPE server may experience high CPU after the agent task is started. The ABEND0C4 can occur at two offsets (at the PK87219 level) in R420: KO2XSYS2+296C on a 5870700C involves a (LOAD) instruction, KO2XSYS2+2086 on a D5037004A6C8 involves a (CLC) instruction. Since the RMVT pointer to the z/OS DB2 RMVT in the Omegamon control block $TCA is zeros, KO2XSYS2 ABENDs trying to access values base on the RMVT. The real problem is that KO2XSYS2 shouldn't have been called in this case, it expects RMVT pointer and other pointers to DB2 control blocks to be valid.
Local fix
Set AUTODETECT=NO and specify target DB2's to monitor in OMPEMSTR.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - PE Server subtask * * - The component that transfers DB2 * * monitoring data collected by the * * OMEGAMON collector to the TEMA * **************************************************************** * PROBLEM DESCRIPTION: A PE Server subtask is started for an * * autodetected Group Attach name of a * * Data Sharing Group. When a Tivoli * * Enterprise Monitoring Agent (Agent) * * connects to this PE Server subtask, the * * Agent D5 might enter a loop and cause * * high CPU consumption or abend with * * S0C4. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: When the OMEGAMON Collector PE Server subtask is configured with option AUTODETECT activated and a member of a Data Sharing Group (DSG) is active, a PE Server subtask is started and connects to the Group Attach name of the DSG. In this case the set up of the PE Server subtask is not correct. When a Tivoli Enterprise Monitoring Agent (Agent) connects to this PE Server subtask, the Agent D5 might enter a loop and cause high CPU consumption or abend with S0C4. PROBLEM CONCLUSION: With option AUTODETECT activated a PE Server subtask will be started to monitor a local member of a Data Sharing Group (DSG) only if it can explicitely connect to the specific DB2 subsystem. Autodetected Group Attach names of a DSG are ignored. KEYWORDS: GROUP-ATTACH HIGH-CPU D5 AGENT KO2ACONB ABENDS0C4
Problem conclusion
With option AUTODETECT activated a PE Server subtask will be started to monitor a local member of a Data Sharing Group (DSG) only if it can explicitely connect to the specific DB2 subsystem. Autodetected Group Attach names of a DSG are ignored. KEYWORDS: GROUP-ATTACH HIGH-CPU D5 AGENT KO2ACONB ABENDS0C4
Temporary fix
Comments
APAR Information
APAR number
PK93393
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-08-07
Closed date
2009-08-12
Last modified date
2010-07-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK49185
Modules/Macros
DGOVMSTR DGOVRSFI DGOZCAF
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R420 PSY UK49185
UP09/08/26 P F908
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
22 July 2010