Error description
ABEND0C4 in DSQISDT8 at displacement X'AAC'. QMF is moving 1 byte too many off of the end of a buffer.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All QMF for TSO/CICS V810 and V910 * * users. * **************************************************************** * PROBLEM DESCRIPTION: Issuing the SAVE DATA command for * * reports or tables that contain * * decimal columns can result in an * * ABENDS0C4 in DSQISDT8. * **************************************************************** * RECOMMENDATION: * **************************************************************** The code that moves decimal data from one buffer to another was using an incorrect length. If the data in the FROM buffer is at the very end of storage allocated for that buffer, and if storage beyond that buffer is fetch protected, using the incorrect (too large) length results in an ABENDS0C4 PIC11.
Problem conclusion
The copy instruction has been altered to fetch the correct length of data.
Temporary fix
Comments
APAR Information
APAR number
PK92062
Reported component name
QMF-QUERY MGMT
Reported component ID
566872101
Reported release
810
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-07-22
Closed date
2009-07-28
Last modified date
2009-08-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK48780 UK48781
Modules/Macros
DSQESDT8 DSQFSDT8 DSQISDT8
Fix information
Fixed component name
QMF-QUERY MGMT
Fixed component ID
566872101
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCWRCK","label":"QMF for TSO\/CICS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
03 August 2009