IBM Support

PK90765: TRANSACTIONS NOT PROPERLY ROUTED WITH IMS V10

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • WLR V2.5 does not route transactions when PRCHNG/PRISRT calls
    are made and no PRCHNG/PRISRT entry points are provided in the
    DFSMSCE0 exit when executing under IMS V10.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Workload Router V2.5 for IMS V10.   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Transactions not properly routed        *
    *                      with IMS V10.                           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    WLR V2.5 does not route transactions when PRCHNG/PRISRT calls
    are made and no PRCHNG/PRISRT entry points are provided in the
    DFSMSCE0 exit when executing under IMS V10.
    When a customized DFSMSEC0 without PRCHNG/PRISRT entry points
    defined, Workload Router does not receive control for these
    types of calls.
    

Problem conclusion

  • Module IWXMSCE1 has been modified to correct this problem.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK90765

  • Reported component name

    IMS WLR

  • Reported component ID

    5697B8700

  • Reported release

    251

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2009-07-07

  • Closed date

    2009-07-10

  • Last modified date

    2009-08-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK48285

Modules/Macros

  •    IWXMSCE1
    

Fix information

  • Fixed component name

    IMS WLR

  • Fixed component ID

    5697B8700

Applicable component levels

  • R251 PSY UK48285

       UP09/07/15 P F907

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.