A fix is available
APAR status
Closed as program error.
Error description
MSGIQC3026E issued along with text: EOF before CheckPoint complete An unexpected non-consecutive message caused the issue and we'll need to correct this by issuing a warning message instead of IQC3026E. Additional issue fixed: Running IQCSELCT produces MSGIQC3054T as follows: IQC3054T Checkpoint 2 - No End of CheckPoint Record found, Terminating. Running with the real log (SLDS) does not produce the error, but running with the extracted archive log is when the select error occurs.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of QCF that use QCF methods to rebuild * * the queues. All 3 ways to rebuild the queues * * are impacted : * * - using procedures with IQCSELCT; * * - using batch with CHKPT LAST,..; * * - using skeletons to create rebuild * * procedures. * **************************************************************** * PROBLEM DESCRIPTION: The first log data set is located using * * recons , or is set in the JCL. * * If the first data set occupies several * * volumes-second and next are not read * * - read stop on EOV and the records that * * are on next volumes are not accepted. * * An error message is issued, that the * * end of log data has been reached, but * * the selected checkpoint is not * * completed. * **************************************************************** * RECOMMENDATION: * **************************************************************** The programs are changed to continue reading the log data set's next volumes, after EOV is encounterred.
Problem conclusion
The EOV is recognized now and the read continues.
Temporary fix
Comments
APAR Information
APAR number
PK90263
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-06-30
Closed date
2009-07-10
Last modified date
2009-10-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK48280
Modules/Macros
IQCSSUB6
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R310 PSY UK48280
UP09/07/14 P F907
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]
Document Information
Modified date:
03 October 2020