IBM Support

PK90263: IQC3026E EOF BEFORE CHECKPOINT COMPLETE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • MSGIQC3026E issued along with text:
    EOF before CheckPoint complete
    
    An unexpected non-consecutive message caused the issue and
    we'll need to correct this by issuing a warning message instead
    of IQC3026E.
    
    Additional issue fixed:
    Running IQCSELCT produces MSGIQC3054T as follows:
      IQC3054T Checkpoint  2 - No End of CheckPoint Record found,
      Terminating.
    Running with the real log (SLDS) does not produce the error,
    but running with the extracted archive log is when the select
    error occurs.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of QCF that use QCF methods to rebuild *
    *                 the queues. All 3 ways to rebuild the queues *
    *                 are impacted :                               *
    *                 - using procedures with IQCSELCT;            *
    *                 - using batch with CHKPT LAST,..;            *
    *                 - using skeletons to create rebuild          *
    *                   procedures.                                *
    ****************************************************************
    * PROBLEM DESCRIPTION: The first log data set is located using *
    *                      recons , or is set in the JCL.          *
    *                      If the first data set occupies several  *
    *                      volumes-second and next are not read    *
    *                      - read stop on EOV and the records that *
    *                      are on next volumes are not accepted.   *
    *                      An error message is issued, that the    *
    *                      end of log data has been reached, but   *
    *                      the selected checkpoint is not          *
    *                      completed.                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The programs are changed to continue reading the log data set's
    next volumes, after EOV is encounterred.
    

Problem conclusion

  • The EOV is recognized now and the read continues.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK90263

  • Reported component name

    IMS QUEUE CNTL

  • Reported component ID

    5697E9900

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2009-06-30

  • Closed date

    2009-07-10

  • Last modified date

    2009-10-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK48280

Modules/Macros

  •    IQCSSUB6
    

Fix information

  • Fixed component name

    IMS QUEUE CNTL

  • Fixed component ID

    5697E9900

Applicable component levels

  • R310 PSY UK48280

       UP09/07/14 P F907

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]

Document Information

Modified date: