APAR status
Closed as program error.
Error description
This APAR covers two problems: PE44337-F903 and PE46102-F905. PE44337-F903 After applying PTF UK44337 for APAR PK73193, existing CICS IA users may receive the following messages when starting CICS IA if they have not updated the CICS region options DEFAULTS to specify a resource prefix table value. If the user has not created their own resource prefix table, they can specify a value of CIUPFXTB in the DEFAULTS record or the individual CICS region options. . CIU2204I mm/dd/yy hh:mm:ss <applid> CINT being used by <userid> CIU2240I mm/dd/yy hh:mm:ss <applid> EXEC CICS ENABLE EXIT for program CIUXDUMM, EXIT XICEXP OK CIU2201S mm/dd/yy hh:mm:ss <applid> CICS LOAD failed RESP=27 RESP2=1 RCODE=01000000 CIU2218S mm/dd/yy hh:mm:ss <applid> CINT has abended IUZA in program CIUA110C CIU2105I mm/dd/yy hh:mm:ss <applid> CINT session has ended . CIUA110C successfully does a LOAD for CIUXTRAN and CIUXPROG, but receives a PGMIDERR when loading low values. The low value should have been the LOAD for the default resource prefix table name of CIUPFXTB or the user specified resource prefix table. The name should be in AUGW_RESLIST_NAME and is specified on the AUGW_RESLIST_NAME for the call to the GET_XLIST routine. . CIUA000C should read the DEFAULTS control record and if it exists and the AUCR_GEN2_OPTIONS field at x'21C' is zeros, it should rewrite the record using the CIUPFXTB default value. . Additional Symptom(s) Search Keyword(s): PK73193 TSQUEUE TSQ UK44337 ABENDUIUZA ABENDIUZA blanks null KIXREVPAD
Local fix
1) Run the CINT transaction. 2) Choose option 2 to configure region options. 3) On screen CIU200 choose option 6 for General options. 4) On screen CIU260 specify the default value CIUPFXTB in the Resource prefix list input field. PE46102-F905 After applying PTF UK46102 or UK48312 user may receive the message CIU2246W with zero value of dataspace percent full. CIU3305I 08/19/09 08:00:16 CICSNA32 CINB save started - because of TIME CIU3306I 08/19/09 08:00:16 CICSNA32 CINB save ended - 0 records saved CIU2246W 08/19/09 08:00:16 CICSNA32 CICSIA dataspace is 0 percent full However, displaying the statistics shows the actual value. For example: Table dataspace name . . . : 00000INT 86.3 % full
Problem summary
**************************************************************** * USERS AFFECTED: All CICS IA Version 2.2 users. * **************************************************************** * PROBLEM DESCRIPTION: * * PE44337-F903 * * The problem is caused by new fields * * being added to the existing control * * record and these fields were not * * set to the default values . In this * * case a Resource Prefix List program * * name was added. This was not set to * * the default value and left as blanks. * * On CICS IA startup we tried to LOAD * * this blank program name. * * * * PE46102-F905 * * The message CIU2246W is issued when the * * the dataspace used is greater then 85% * * but the value of percent full in the * * message is zero. * **************************************************************** * RECOMMENDATION: Apply the PTF. * **************************************************************** PE44337-F903 A new procedure has been added,it checks the contents of the control record for values that have not been set. If any values have not been set then it sets it to the default value. PE46102-F905 The DSP_CALC routine in CIUCINB1 pass to the message manager CIUMSGCS zero value to insert into CIU2246W message. This is due to passing an incorrect insert length value of 3 in field CIUM2_I_SUB_1_LEN. The CIUM2_I_SUB_1 field points to STATS_DSPACE_FULL which is a fullword BIN(32). After UK46102 or UK48312, the first 3 bytes of the STATS_DSPACE_FULL will always be 000000 as the last byte will be x'64' or less.
Problem conclusion
UK39133 UK44337 UK46102 UK48312 PE44337-F903 During the first read the control record the values of the fields are checked and abnormal values are replaced by defaults. PE46102-F905 Code has been changed to display the correct value of STATS_DSPACE_FULL with 1 decimal place.
Temporary fix
Comments
ž**** PE09/12/02 FIX IN ERROR. SEE APAR PM02302 FOR DESCRIPTION
APAR Information
APAR number
PK89974
Reported component name
CICS INTER ANAL
Reported component ID
5697J2300
Reported release
220
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-06-26
Closed date
2009-09-14
Last modified date
2009-12-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK50116 UK50117
Modules/Macros
CIUA000C CIUA100C CIUA110C CIUA200C CIUCINB1 CIUINDEX CIUMSGE CIUMSGK
Fix information
Fixed component name
CICS INTER ANAL
Fixed component ID
5697J2300
Applicable component levels
R22K PSY UK50117
UP09/09/22 P F909
R220 PSY UK50116
UP09/09/22 P F909
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPUS","label":"CICS Interdependency Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]