IBM Support

PK88325: USING WORK FILES IN ONE PHASE MODE WITH " LOAD OPTIONS " SELECTED MAY LEAD TO EMPTY ROWS OF DATA IN THE LOAD TABLES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In rare instance, it is possible for the LOADFILE to contain
    blank data. The header information, if any, will still be
    present. This can occur if the job is being run in one-phase
    mode with work files.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: User of DB2 Log Analysis Tool.               *
    ****************************************************************
    * PROBLEM DESCRIPTION: In rare instance, it is possible for    *
    *                      the LOADFILE to contain blank data. The *
    *                      header information, if any, will still  *
    *                      be present. This can occur if the job   *
    *                      is being run in one-phase mode with     *
    *                      work files.                             *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK88325

  • Reported component name

    DB2 LOG ANALYSI

  • Reported component ID

    5655E6601

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2009-06-09

  • Closed date

    2009-07-06

  • Last modified date

    2009-08-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    ALAALA
    

Fix information

  • Fixed component name

    DB2 LOG ANALYSI

  • Fixed component ID

    5655E6601

Applicable component levels

  • R310 PSY UK48109

       UP09/07/11 P F907

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.