A fix is available
APAR status
Closed as program error.
Error description
HPIC wrongly ends with message FABJ0114E if a comma is specified after the DSN= keyword.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 4 Release 1 users ( FMID=H1J0410 ) * **************************************************************** * PROBLEM DESCRIPTION: IMS HP Image Copy wrongly ends with the * * message FABJ0114E ( MSGFABJ0114E ) in * * spite of a correct specification of a * * DSNx= keyword. * * This problem occurs under the following * * condition: * * - A DSNx= keyword followed by a comma * * is specified in an ICEIN control * * statement. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** IMS HP Image Copy wrongly ends with the message FABJ0114E ( MSGFABJ0114E ) in spite of a correct specification of a DSNx= keyword. This problem occurs under the following condition: - A DSNx= keyword followed by a comma is specified in an ICEIN control statement. The cause of this problem is as follows: HPIC has a logic for syntax check of DSNx= keyword. In this logic, an internal flag is used to recognize whether a syntax error exists or not. But HPIC mishandles the flag and an unexpected value is set to the flag. Then HPIC wrongly judges that a syntax error exists.
Problem conclusion
FABJSTMP has been modified to check the syntax of DSNx= keyword correctly.
Temporary fix
Comments
APAR Information
APAR number
PK87615
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-05-29
Closed date
2009-06-10
Last modified date
2009-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK47319
Modules/Macros
FABJSTMP
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R410 PSY UK47319
UP09/06/15 P F906
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.1.0","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: