Error description

  • The DB2 Object Comparison Tool for z/OS issues the message:
    Table partitioning needed for table CHRIS.DPSI
        but no partitioning info available from index/table
      Unable to convert to table-controlled partitioning
      GOCC002E - Severe error. Compare terminates
    when the source DDL contains only a new DPSI index.
    

Local fix

  • Use complete DDL for the objects in addition to the new index
    DDL.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Object Comparison tool.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Compare failed with return code 12 and  *
    *                      with the following messages:            *
    *                                                              *
    *                      "Table  partitioning  needed  for table *
    *                       'owner.DPSI',    but  no  partitioning *
    *                       information available from index/table *
    *                       Unable to convert  to table-controlled *
    *                       partitioning  GOCC002E - Severe error. *
    *                       Compare terminates"                    *
    ****************************************************************
    * RECOMMENDATION: Apply The PTF.                               *
    ****************************************************************
    The source DDL has only one object i.e index(DPSI).
    The Target has Tablespace, Table, index.
    
    When compared with KEEPTGT option, compare failed in merge
    expecting table definition as part of source DDL.
    

Problem conclusion

  • Resolved. When table definition is missing, Merge will let the
    DPSI be simply passed on.  In the customer scenario, the delta
    change  would be to add additional index(DPSI) onto target.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK86126

  • Reported component name

    DB2 OBJECT COMP

  • Reported component ID

    5697G6400

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-05-07

  • Closed date

    2009-08-20

  • Last modified date

    2009-09-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    ADBCCMM
    

Fix information

  • Fixed component name

    DB2 ADMIN TOOL

  • Fixed component ID

    568851500

Applicable component levels

  • R720 PSY UK49451

       UP09/08/27 P F908

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSCVQTD","label":"IBM Db2 Administration Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]