Error description

  • DRF Master HPIC in DRF Address Space terminates with ABENDS0C4
    when processed DBDS is more than 700 and the output image copy
    is required under DRF.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 1 users ( FMID=H1J0410 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: HPIC V4R1 under IMS Database Recovery   *
    *                      Facility (DRF) Version 3 Release 1 has  *
    *                      following problems:                     *
    *                                                              *
    *                      - HPIC Image Copy function terminates   *
    *                        with ABEND S0C4 ( ABEND0C4 ) when the *
    *                        number of processing database data    *
    *                        sets are over 681.                    *
    *                                                              *
    *                      - HPIC Image Copy function terminates   *
    *                        with ABEND S0C4 ( ABEND0C4 )          *
    *                        at FABJCP40 CSECT FABJCP40 + X'296'   *
    *                        when the number of unprocessed DBDSs  *
    *                        divided by 20 is 19.                  *
    *                                                              *
    *                      And also, HPIC provides the following   *
    *                      enhancement under IMS Database Recovery *
    *                      Facility (DRF) Version 3 Release 1.     *
    *                                                              *
    *                      - The maximum number of processed DBDS  *
    *                        in HPIC Image Copy function is        *
    *                        changed to 4095 from 999.             *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    HPIC V4R1 under IMS Database Recovery Facility (DRF) Version 3
    Release 1 has following problems:
    
    - HPIC Image Copy function terminates with ABEND S0C4
      ( ABEND0C4 ) when the number of processing database data
      sets are over 681. The cause of this problem is that
      work area which stores the length of HPIC control block is
      small.
    
    - HPIC Image Copy function terminates with ABEND S0C4
      ( ABEND0C4 ) at FABJCP40 CSECT FABJCP40 + X'296'
      when the number of unprocessed DBDSs divided by 20 is 19.
    
      HPIC obtains buffer storage in which HPIC keeps up to 20
      messages of the DFSPRINT DD. When that buffer storage becomes
      full, HPIC writes the kept 20 messages in the DFSPRINT DD and
      the buffer storage is initialized to keep next messages.
      But HPIC mishandles the counter to check that the buffer is
      full, so HPIC tries to write 21th message and reference the
      storage that is not accessible and terminates with abend.
    
      This APAR fixes the above problem and HPIC Image Copy function
      terminates with RC=16 and the message FABJ0192E
      ( MSGFABJ0192E ) on the conditions above.
    
    And also, this APAR provides the following enhancement under IMS
    Database Recovery Facility (DRF) Version 3 Release 1.
    
    - The maximum number of processed DBDS in HPIC Image Copy
      function is changed to 4095 from 999.
    

Problem conclusion

  • FABJDIB and FABJMAS1 have been modified to extend the area that
    length of data space is stored.
    
    FABJINT3 has been modified to change the maximum number of image
    copy data sets dynamically allocated from 999 to 4095.
    
    FABJTERM has been modified to write the kept messages in the
    DFSPRINT DD and initialize the buffer storage when the number of
    the kept messages reached the maximum.
    
    FABJSAS2 has been reassembled.
    
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    IMS High Performance Image Copy for z/OS Version 4 Release 1
    User's Guide SC18-9409-02 ( SC18940902 ) should be changed as
    follows:
    
    12.0 Reference: Return codes, abend codes, and messages
     12.3 Messages
      12.3.168 FABJ3915E
    
      Explanation:
        An attempt to assign a unique ddname for the image copy data
        set requested by the ICOUT=* failed. The cause of this error
        might be due to the number of image copy data sets exceeding
    |   the maximum value of 4095.
      System Action:
    |   IMS HP Image Copy issues a user error abend code of 3915.
      Programmer Response:
        Separate the job steps into two so that the number of the
        image copy data sets is less than the maximum. Rerun the
        job. If the problem recurs, contact IBM Software Support.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK85898

  • Reported component name

    IMS DB RECOVERY

  • Reported component ID

    5655I4400

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2009-05-05

  • Closed date

    2009-05-22

  • Last modified date

    2009-06-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK46822

Modules/Macros

  • FABJDIB  FABJINT3 FABJMAS1 FABJSAS2 FABJTERM
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R410 PSY UK46822

       UP09/05/27 P F905

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"310","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020