IBM Support

PK84778: KO2O1364E NTH COLLECTION IS SUSPENDED, REASON CALL$PUT. LOGON TO CLASSIC FAILS, POSSIBLE LOOP

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After apply of UK42615 customer gets KO2O1364E NEAR-TERM HISTORY
    DATA COLLECTOR - SEQUENTIAL COLLECTION SUSPENDED.REASON CALL$PUT
    (WRITESEQ) when attempting to allocate NTH dynamic sequential
    dataset.  If MGMTCLAS and/or STORCLAS parms of the COPTxxxx
    member are taken out, logon to Classic is possible, but the
    dynamic NTH sequential dataset is allocated using a default
    MGMTCLAS, not what was specified in ICAT.
    This could also result in a loop in the OM PE Server STC, a /P
    won't bring it down, you have to CANCEL it.
    The loop shows up in SYSTRACE as an ABEND0C4-04 in
    KO2HSVPB+654 (at PK78738 level) on a 58F0F010 instruction,
    accessing KEY8 storage with a PSW KEY of KEY7.  The storage
    KEY was not preserved properly and when R8 was used to reset
    it, the resulting KEY was KEY7 and not KEY8.  Since KO2HSVPB
    was in code to handle an unexpected program check already, the
    invalid KEY resulted in another program check and this led
    KO2HSVPB into the loop.
    

Local fix

  • provide UNIT(SYSDA) in COPTxxxx
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Classic Interface                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: Message KO2O1364E NTH COLLECTION IS     *
    *                      SUSPENDED.  REASON CALL$PUT.            *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    Support for new SEQ dataset allocation keyword UNIT failed if
    the UNIT keyword was missing.  A loop will occur which uses 10
    CPU seconds until timeout.
    
    PROBLEM CONCLUSION:
    Change the allocation code to work with or without the UNIT
    parameter.
    

Problem conclusion

  • Change the allocation code to work with or without the UNIT
    parameter.
    
    KEYWORDS : NEAR TERM HISTORY NTH KO2O1364E
               SEQ DATASET ALLOCATION
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK84778

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-04-15

  • Closed date

    2009-04-27

  • Last modified date

    2009-06-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK46039

Modules/Macros

  • KO2$QIOB KO2HSVPB
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK46039

       UP09/05/06 P F905

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
09 June 2009