Error description
After apply of UK42615 customer gets KO2O1364E NEAR-TERM HISTORY DATA COLLECTOR - SEQUENTIAL COLLECTION SUSPENDED.REASON CALL$PUT (WRITESEQ) when attempting to allocate NTH dynamic sequential dataset. If MGMTCLAS and/or STORCLAS parms of the COPTxxxx member are taken out, logon to Classic is possible, but the dynamic NTH sequential dataset is allocated using a default MGMTCLAS, not what was specified in ICAT. This could also result in a loop in the OM PE Server STC, a /P won't bring it down, you have to CANCEL it. The loop shows up in SYSTRACE as an ABEND0C4-04 in KO2HSVPB+654 (at PK78738 level) on a 58F0F010 instruction, accessing KEY8 storage with a PSW KEY of KEY7. The storage KEY was not preserved properly and when R8 was used to reset it, the resulting KEY was KEY7 and not KEY8. Since KO2HSVPB was in code to handle an unexpected program check already, the invalid KEY resulted in another program check and this led KO2HSVPB into the loop.
Local fix
provide UNIT(SYSDA) in COPTxxxx
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: Message KO2O1364E NTH COLLECTION IS * * SUSPENDED. REASON CALL$PUT. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Support for new SEQ dataset allocation keyword UNIT failed if the UNIT keyword was missing. A loop will occur which uses 10 CPU seconds until timeout. PROBLEM CONCLUSION: Change the allocation code to work with or without the UNIT parameter.
Problem conclusion
Change the allocation code to work with or without the UNIT parameter. KEYWORDS : NEAR TERM HISTORY NTH KO2O1364E SEQ DATASET ALLOCATION
Temporary fix
Comments
APAR Information
APAR number
PK84778
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-04-15
Closed date
2009-04-27
Last modified date
2009-06-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK46039
Modules/Macros
KO2$QIOB KO2HSVPB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK46039
UP09/05/06 P F905
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]