Error description

  • The DB2 Object Comparison Tool for z/OS uses different methods
    to constructing the DSN of the converted unload data set. This
    APAR will consolidate this into a single method.
    If ADB2UCUS variables ASYRECD and ASYRECG differ, LOAD will fail
    with DSN not found.
    

Local fix

  • Ensure ADB2UCUS variables ASYRECD and ASYRECG are the same
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Object Comparison               *
    *                 Tool for z/OS who defines different          *
    *                 values for variables ASYRECD and             *
    *                 ASYRECG in ADB2UCUS                          *
    *                 and uses WSL to apply the change.            *
    ****************************************************************
    * PROBLEM DESCRIPTION: DB2 Object Comparison Tool for          *
    *                      z/OS uses different methods to          *
    *                      construct the DSN of the converted      *
    *                      unload data set. If the ADB2UCUS        *
    *                      variables ASYRECD and ASYRECG           *
    *                      differ, the LOAD will fail with a       *
    *                      'DSN not found' error.                  *
    ****************************************************************
    * RECOMMENDATION: Apply The PTF.                               *
    ****************************************************************
    DB2 Object Comparison Tool for z/OS uses different
    methods to construct the DSN of the converted unload
    data set. If the ADB2UCUS variables ASYRECD and
    ASYRECG differ, the LOAD will fail with a 'DSN not found'
    error.
    

Problem conclusion

Temporary fix

Comments

  • The skeleton GOC72AC has been modified by adding
    the ULCDSN section with the correct converted unload
    data set name. ADB27AC can generate the consistent
    converted unload data set name in the CNC file.
    

APAR Information

  • APAR number

    PK84634

  • Reported component name

    DB2 OBJECT COMP

  • Reported component ID

    5697G6400

  • Reported release

    720

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-04-14

  • Closed date

    2010-08-26

  • Last modified date

    2010-09-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK60018

Modules/Macros

  •    GOC27AC
    

Fix information

  • Fixed component name

    DB2 OBJECT COMP

  • Fixed component ID

    5697G6400

Applicable component levels

  • R720 PSY UK60018

       UP10/08/31 P F008

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUVH","label":"IBM Db2 Object Comparison Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 February 2021