Error description
For the following egl code the generated cobol is incorrect: sysVar.transferName = ' '; show PD0120K_UI returning to sysVar.transferName; The generator sets an incorrect SSM flag and the the client side does not navigate to the intended page.
Local fix
Problem summary
When the SHOW ?UI-record? returning to statement is generated, the code sets an SSM flag, even if the returning to clause is blank, which tells the web transaction gateway to keep the application handler. If navigation returns to this application, the UI will be redisplayed instead of calling the web transaction again.
Problem conclusion
A COBOL generator fix was made to check the returning to clause for blanks. If the SHOW specifies a returning to that is blank, the SSM flag is not set so that the web transaction gateway will discard the handler. A work around is to code the SHOW without the returning to clause.
Temporary fix
Comments
APAR Information
APAR number
PK81936
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-03-05
Closed date
2009-03-20
Last modified date
2009-03-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R710 PSN
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
20 March 2009