Error description

  • Here is a list of items being addressed:
    1. The incorrect FSE is set to the segment of SDEP when
       recovering with X'4026' log.
    2. IMS V6 APAR: PQ05913 changed the length of the work area that
       is passed to IMS user exit: DFSFLGX0.
       DFR is not yet enhanced for this apar.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS DEDB FAST RECOVERY Version 2         *
    *                 Release 2 (FMID=H1J2220) users in IMS V8, V9 *
    *                 or V10.                                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Various problems of DFR detected as the *
    *                      results of an additional code review    *
    *                      and tests.                              *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    The following problems are fixed by this APAR:
    1. The incorrect FSE is set to the segment of SDEP when
       recovering with X'4026' log.
    
       The DFR processes the IOT-EEQE log (X'4026') for the segment
       of SDEP.
       At the time, since DFR sets the access mode and issues the
       ICM instruction using the GPR15 for obtaining the FSE value
       after AR15 is used as work register for the GETMAIN macro by
       the system, the right value for FSE is not obtained.
    
    2. IMS V6 APAR: PQ05913 changed the length of the work area that
       is passed to IMS user exit: DFSFLGX0.
       DFR is not yet enhanced for this apar.
    
       APAR: PQ05913 increases the size of this work area from 256
       bytes to 512 bytes.
    

Problem conclusion

  • The following modules and macros have been modified.
    (x = 8, 9 or A)
    *
    DFRARMOx  - When FUNC=SET is specified, the DFRARMOx macro
                issues a DFRARCLx macro for clearing all ARs, before
                setting the access mode.
    DFRCMRCx  - This module was changed so that all ARs to be used
                are specified to the DFRARMOx macro reflecting the
                change of the DFRARMOx macro.
    DFRNLG0x  - This module was changed so that the FSE value of the
                segment of SDEP is not changed when the X'4026 log
                is processed.
    DFRLFRCx  - This module was changed so that the DFRARCLx macro
                is not issued before issuing the DFRARMOx macro
                reflecting the change of the DFRARMOx macro.
    DFRNLGEx  - This module was changed so that the size of the work
                area for IMS user exit:DFSFLGX0 is increased from
                256 bytes to 512 bytes.
    *
    DFRLFCKx +- These modules were modified to be re-assembled to
    DFRLFTLx |  reflect the change.
    DFRL591x |
    DFRL593x |
    DFRL595x |
    DFRNFSTx |
    DFRNLP2x |
    DFRNRCKx |
    DFRNRDOx |
    DFRNWPDx +
    *
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK80666

  • Reported component name

    DEDB FAST RECOV

  • Reported component ID

    5655E3200

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-02-13

  • Closed date

    2009-02-18

  • Last modified date

    2009-03-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK44128

Modules/Macros

  • DFRARMOA DFRARMO8 DFRARMO9 DFRCMRCA DFRCMRC8
    DFRCMRC9 DFRLFCKA DFRLFCK8 DFRLFCK9 DFRLFRCA DFRLFRC8 DFRLFRC9
    DFRLFTLA DFRLFTL8 DFRLFTL9 DFRL591A DFRL5918 DFRL5919 DFRL593A
    DFRL5938 DFRL5939 DFRL595A DFRL5958 DFRL5959 DFRNLGEA DFRNLGE8
    DFRNLGE9 DFRNLG0A DFRNLG08 DFRNLG09 DFRNLP2A DFRNLP28 DFRNLP29
    DFRNRCKA DFRNRCK8 DFRNRCK9 DFRNRDOA DFRNRDO8 DFRNRDO9 DFRNWPDA
    DFRNWPD8 DFRNWPD9
    

Fix information

  • Fixed component name

    DEDB FAST RECOV

  • Fixed component ID

    5655E3200

Applicable component levels

  • R220 PSY UK44128

       UP09/02/20 P F902

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX895","label":"IMS DEDB Fast Recovery"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: