APAR status
Closed as program error.
Error description
When VisualAge Generator does a comparison of CHARacters and zon ed NUMbers, it performs a byte by byte comparison by left justif ying the NUM value and then compared it to the text. This can produce unusual results in the 'if' statement, and even allow non-numeric values to be used from the zoned number source. In Rational Business Developer - Enterprise Generation Language, when a comparison of a text with a number is done, the text is converted to a valid number and then mathematically compared to the number. This could produce a different result than VAGen. A warning should be given in the EGL editor when comparing text and numbers. LOCAL FIX:
Local fix
Problem summary
The real problem here is that integer literals were treated as NUM in vag and v6.x. They were changed to INT in 7.0. This causes the runtime to have to translate the character code into a numeric.
Problem conclusion
A new build descriptor optiion has been introduced (v60NumWithCharBehavior) that will allow the customer to go back to the original VAG/V6x functionality. So, no warning message is needed.
Temporary fix
Comments
APAR Information
APAR number
PK80202
Reported component name
RBD EGL FOR COB
Reported component ID
5724S5001
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-02-06
Closed date
2009-03-20
Last modified date
2009-03-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R710 PSN
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]