A fix is available
APAR status
Closed as program error.
Error description
Overlay of IMS control region address space private storage when a segment passed to the AOI exit exceeds 466 bytes. Message CCF8107E may also be issued with RC08 reason code 0809. Random ABEND0C4's follow MSGCCF8107E.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CCF V2.1 users. * **************************************************************** * PROBLEM DESCRIPTION: Message CCF8107E IXGWRITE ERROR * * RC=00000008 RSN=00000809 can occur * * when a message segment longer than * * 466 bytes is passed to the CCF AOI * * exit routine. * **************************************************************** * RECOMMENDATION: * **************************************************************** Message CCF8107E IXGWRITE ERROR RC=00000008 RSN=00000809 can occur when a message segment longer than 466 bytes is passed to the CCF AOI exit routine. Storage overlays in the IMS private area are also possible.
Problem conclusion
Ensure that truncation of messages longer than 466 bytes take into account message header data to prevent overlays. Deterine the maximum logstream buffer size when CCF connects the log stream, and ensure that buffers written do not exceed the maximum buffer size.
Temporary fix
Comments
APAR Information
APAR number
PK77453
Reported component name
IMS COMMAND CTL
Reported component ID
5655F4000
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-12-12
Closed date
2009-01-12
Last modified date
2009-02-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK43067
Modules/Macros
CCFAOE00 CCFAOUEA CCFAOUE8 CCFAOUE9 CCFLOGC0 CCFOPST0
Fix information
Fixed component name
IMS COMMAND CTL
Fixed component ID
5655F4000
Applicable component levels
R210 PSY UK43067
UP09/01/13 P F901
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY6","label":"IMS Command Control Facility"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]
Document Information
Modified date:
21 October 2020