Error description

  • -  ABENDS0C4 INTC 10 OR 11 IN IZTCSA03.  THIS ABEND COULD
    HAPPEN DURING IMS RESTART, EXECUTING THE ONLINE TABLE
        REFRESH IN IZTRAN OR AS PART OF THE BATCH RELOAD (IZTLOAD).
     -  MEMBER IZTD1INI OF AIZTSAMP CONTAINS AN INCORRECT JCL
       PARAMETER (STORCLASS).
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS ETO Support users.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABENDS0C4 INTC 10 or 11 in IZTCSA03.    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    1. ABENDS0C4 INTC 10 or 11 in IZTCSA03. This abend could happen
    during IMS RESTART, executing the Online Table Refresh in
    IZTRAN or as part of the batch reload (IZTLOAD).
    2. Memebr IZTD1INI of AIZTSAMP contains an incorrect JCL
    parameter (STORCLASS).
    

Problem conclusion

  • 1. The ABENDS0C4 occurs when module IZTCSA03 is attempting to
    determine the protect key of the storage that is to be freed.
    At the point of the failure IZTCSA03 is running disabled
    for interrupts, and if the table is paged out the abend will
    occur.
    Program IZTCSA03 has been changed to test the storage protect
    key before it becomes disabled for interrupts.
    2. The spelling of STORCLAS has been corrected in AIZTSAMP.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK76209

  • Reported component name

    IMS ETO SUPPORT

  • Reported component ID

    5655E1200

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-11-21

  • Closed date

    2008-11-24

  • Last modified date

    2008-12-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK41884

Modules/Macros

  • IZTCSA03 IZTD1INI
    

Fix information

  • Fixed component name

    IMS ETO SUPPORT

  • Fixed component ID

    5655E1200

Applicable component levels

  • R310 PSY UK41884

       UP08/11/26 P F811

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX897","label":"IMS ETO Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 December 2008