Error description

  • No threads shown if AUTODETECT=NO for config. with two members
    of same DSG on same LPAR and only one being configured
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   PE Server subtask                        *
    *                 -   Classic Interface                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: When members of a Data Sharing Group    *
    *                      are running on the same LPAR and the    *
    *                      OMEGAMON Collector is configured with   *
    *                      option AUTODETECT set to NO and the     *
    *                      scope in the Classic Interface (VTAM)   *
    *                      is set to S for a local member which    *
    *                      was not configured in ICAT, VTAM will   *
    *                      not display thread data.                *
    *                      Message FPEV3016W is issued to the PE   *
    *                      Server subtask log (SYSPRINT).          *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    During start up the OMEGAMON Collector starts PE Server subtasks
    for each configured or automatically detected DB2 Subsystem.
    The Classic Interface can then monitor local DB2 Subsystems for
    which a PE Server subtask is up and running as well as remote
    members of a Data Sharing Group for which a local monitored
    member exists. When the Classic Interface issues data retrieval
    requests for local members with scope single (S), the request
    is routed to the monitoring PE Server subtask and will fail if
    the monitoring PE Server subtask is not up and running.
    
    PROBLEM CONCLUSION:
    When members of a Data Sharing Group are running on the same
    LPAR and the OMEGAMON Collector is configured with option
    AUTODETECT set to NO and the scope in the Classic Interface
    (VTAM) is set to a local member which was not configured in
    ICAT but another local member of the same Data Sharing Group is
    monitored on the same LPAR, VTAM will display the requested
    thread data for the selected local member.
    When the Classic Interface issues data retrieval requests for a
    local member of a Data Sharing Group with scope single (S), the
    requests are routed to the monitoring PE Server subtask or to
    the PE Server subtask which monitors another local member of
    the same Data Sharing Group.
    

Problem conclusion

  • When members of a Data Sharing Group are running on the same
    LPAR and the OMEGAMON Collector is configured with option
    AUTODETECT set to NO and the scope in the Classic Interface
    (VTAM) is set to a local member which was not configured in
    ICAT but another local member of the same Data Sharing Group is
    monitored on the same LPAR, VTAM will display the requested
    thread data for the selected local member.
    When the Classic Interface issues data retrieval requests for a
    local member of a Data Sharing Group with scope single (S), the
    requests are routed to the monitoring PE Server subtask or to
    the PE Server subtask which monitors another local member of
    the same Data Sharing Group.
    * The service level of the                                     *
    * OMEGAMON collector PE Server subtask                         *
    * FPEV0000I  DATA SERVER INITIALIZATION                        *
    * FPEV0114I  PTF BUILD IS 09.188
    
    KEYWORDS :
    FPEV3016W VTAM THREAD SUMMARY DSG SCOPE SINGLE LOCAL MEMBER
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK75757

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-11-18

  • Closed date

    2009-07-16

  • Last modified date

    2009-08-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK41864 PK93794

Modules/Macros

  •    DGOVISI  DGOVISIT DGOVMDSP DGOVMSTR DGOVPIG1
    DGOVPP1  DGOVRPRM DGOVRSFI DGOVRTG0 DGOVRTG1 DGOZCAF  FPEVMST1
    FPEVM000 KO2PROU
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK41864

       UP09/07/22 P F907

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410"}]

Document Information

Modified date:
31 March 2021