Error description
This APAR will add support to CEX for the IMS synchronous SPE for IMS V10 and IMS Connect V10. The following IMS APARs add the function: PK70078, PK70330, and PK71135. KEYWORDS: IMSV10TGT/K The APAR will also be used to address the problem where inactive IMS Connect systems can cause poor performance when accessing the Operations panel of the CEX ISPF Console.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Users of IMS Connect Extensions V2.1. * **************************************************************** * PROBLEM DESCRIPTION: This APAR will add support to CEX for * * the IMS synchronous SPE for IMS V10 and * * IMS Connect V10. * **************************************************************** * RECOMMENDATION: * **************************************************************** 1. IMS has provided an SPE that enables an IMS application to perform a Sync Callout request from IMS. 2. Status Monitor Ports/Systems views do not show any rows and error message CEXG009 "Invalid action" is issued when the enter key is pressed. The problem is caused by a temporary C++ ostringstream string object being destroyed before it is referenced. The dynamic area panel row appears to be empty, but actually contains a row of low-values. 3. The CEX service exit CEXSVC01 may fail to initialize and/or abend 0C4 if it is active and CEX is not included in the ICON execution. this is due to the change in the exit paramater list for V11. 4. When a very large buffer is returned as a result of an ODBA request, a torage overlay can result processing the event record associated with the request. The storage overlay often results in an abend 0C4 at the entry to module FUNTDB01. 5. If an IMS Connect command is issued after the CLOSEHWS command is issued, a recursive 0C4 abend loop may occur in the SVC screening routine CESSSRTN. This is due to the screening routine not properly dealing with deactivation when IMS Connect is closing down.
Problem conclusion
Temporary fix
Comments
1. Support has been added to CEX to detect and report on Sync Callout activity. 2. A deep copy is taken of the C++ ostringstream string object before referencing the internal buffer to fill the dynamic area panel row. 3. Changed the CEX service exit to detect the version of IMS Connect and use the proper exit offsets during initialization 4. Changed module CEXTECL to limit the amount of the returned buffer recorded so that the event record buffer is not overrun. 5. Changed module CEXSSRTN to detect the end of the IMS Connect activation and proper deactive SVC screening.
APAR Information
APAR number
PK74985
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
210
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function
Submitted date
2008-11-04
Closed date
2009-02-24
Last modified date
2010-08-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK44288
Modules/Macros
CEXACLR1 CEXACL10 CEXCONS CEXCONSS CEXCR62 CEXCSKT CEXEVTPR CEXEVT01 CEXEXRTR CEXGLBLS CEXINTST CEXIVP01 CEXMAIN CEXOPDRV CEXPRED0 CEXPRED1 CEXPUBMN CEXR163 CEXR164 CEXSALUT CEXSBLKF CEXSSRTN CEXSVC01 CEXTECL CEXTECL1
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R210 PSY UK44288
UP09/02/27 P F902
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210"}]
Document Information
Modified date:
22 October 2020