A fix is available
APAR status
Closed as program error.
Error description
Bind Manager program BNDA036 may issue a FREE PACKAGE command on a package that should not be freed.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of Bind Manager. * **************************************************************** * PROBLEM DESCRIPTION: BNDA036 fails to find timestamps in * * certain load modules. * * * * * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** LOAD macro does not return correct module length when PDSEs are used; BNDA036 object code scan was terminating before all text was scanned.
Problem conclusion
Use a different API to obtain module length.
Temporary fix
Comments
APAR Information
APAR number
PK74475
Reported component name
DB2 BIND MANAGE
Reported component ID
5655E4301
Reported release
230
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-10-24
Closed date
2008-11-24
Last modified date
2008-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK41894
Modules/Macros
BNDA040
Fix information
Fixed component name
DB2 BIND MANAGE
Fixed component ID
5655E4301
Applicable component levels
R230 PSY UK41894
UP08/11/26 P F811
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.3.0"}]
Document Information
Modified date:
30 March 2021