Error description
Compare generates message GOCC032E - Duplicate record was detected for . Additional warning message(s) will be issued: Error probably caused by masking. Additional symptoms: msgGOCC032E cc12
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Object Compare Ver 7.2. * **************************************************************** * PROBLEM DESCRIPTION: Object Compare issue the following * * message when Table and Alias are found * * on the source have the same name after * * masking: * * GOCC032E - Duplicate record was * * detected for C2.T2. * * GOCC002E - Severe error. * * Compare terminates. * * Customer complains that * * this message is misleading * **************************************************************** * RECOMMENDATION: Apply The PTF. * **************************************************************** Object Compare issue the following message when Table and Alias found on source have the same name after masking: GOCC032E - Duplicate record was detected for C2.T2 GOCC002E - Severe error. Compare terminates. Customer complains that this message is misleading. GOC was changed to add the additional diagnostic messages: 1) If the problem is caused by masking: GOCC025E - Duplicate record was detected for object C2.T2 Error probably caused by masking. Run will terminate. 2) If the problem is caused by rename: GOCC025E - Duplicate record was detected for object C1.T1 Error probably caused by rename of object from C1.T1 to C2.T2.
Problem conclusion
The problem has been fixed in Object Compare Ver 7.2.
Temporary fix
Comments
APAR Information
APAR number
PK74046
Reported component name
DB2 ADMIN TOOL
Reported component ID
568851500
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-10-17
Closed date
2008-11-13
Last modified date
2008-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
GOC2CMR
Fix information
Fixed component name
DB2 OBJECT COMP
Fixed component ID
5697G6400
Applicable component levels
R720 PSY UK41565
UP08/11/21 P F811
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUVH","label":"IBM Db2 Object Comparison Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]