Error description

  • ABEND0C4-11 FPEVDB2I+48CE on a 0E68 (MVCL) instruction,
    R8 bad.
    PSW AT TIME OF ERROR  078D0000   9A38C96E  ILC 2  INTC 11
      ACTIVE LOAD MODULE           ADDRESS=1A3880A0  OFFSET=000048CE
      NAME=FPEVDB2I
      DATA AT PSW  1A38C968 - 187B5880  C0000E68  47F0A062
    NAME=FPEVDB2I (at PK73617 level)
    DATA AT PSW  1A38C968 - 187B5880  C0000E68  47F0A062
    

Local fix

  • First relief for the 0C4 is included in PK76500, reducing
    the number of follow-on abends and cleanly restarting the
    instance.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   PE Server subtask                        *
    *                 -   Classic Interface                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND S0C4 in module FPEVDB2I with      *
    *                      ILC 2 and INTC 11. Data at PSW is 0E68. *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    When data retrieval requests are issued from the Classic
    Interface (VTAM), the DB2 interface module FPEVDB2I of the
    corresponding PE Server subtask might sporadically cause an
    ABEND S0C4 during copy processing of the performance data
    returned from DB2. The abend is caused by an intermittent
    mismatch in the sizes of the used buffers.
    
    PROBLEM CONCLUSION:
    The sizes of the buffers are verified to match before data are
    copied.
    The code has been corrected accordingly.
    

Problem conclusion

  • The sizes of the buffers are verified to match before data are
    copied.
    The code has been corrected accordingly.
    
    KEYWORDS :
    ABEND S0C4 FPEVDB2I
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK73913

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-10-17

  • Closed date

    2009-01-20

  • Last modified date

    2017-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK43214

Modules/Macros

  •    DGOVISI  DGOVMSTR FPE@DB2I FPEVDB2I FPEVREQ0
    HKDB410J KDB410J
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK43214

       UP09/01/22 P F901

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]