Fixes are available
APAR status
Closed as program error.
Error description
The portlet state is not restored when going back from edit mode to view mode in a portlet where the automaximize setting has been set as init parameter in the portlet.xml.
Local fix
Enable automaximize globally instead
Problem summary
The portlet state is not restored when going back from edit mode to view mode in a portlet where the automaximize setting has been set as init parameter in the portlet.xml.
Problem conclusion
Identify init parameter com.ibm.portal.automaximize to be set to true to enable state restore. Failing Module(s): Engine: State handling Affected Users: All Users Version Information: Portal Version(s): 6.0.1.3 Pre-Requisite(s): PK66847 Co-Requisite(s): --- Portal Version(s): 6.0.1.4 Pre-Requisite(s): Co-Requisite(s): --- Platform Specific: This fix applies to all platforms. A fix is available from Fix Central: http://www.ibm.com/eserver/support/fixes/fixcentral/swgquickorde r?apar=PK73611&productid=WebSphere%20Portal&brandid=5 You may need to type or paste the complete address into your Web browser.
Temporary fix
Comments
APAR Information
APAR number
PK73611
Reported component name
WEBSPHERE PORTA
Reported component ID
5724E7600
Reported release
60G
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-10-10
Closed date
2008-10-20
Last modified date
2008-10-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE PORTA
Fixed component ID
5724E7600
Applicable component levels
R60G PSY
UP
R60H PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSHRKX","label":"WebSphere Portal"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1.3","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: