IBM Support

PK73041: EAV SUPPORT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • EAV (Extended Address Volume) support for High Performance
    Pointer Checker.  EAV is a DASD storage that has 65,521 or
    larger cylinders supported by z/OS 1.10.
    KEYWORD: EAV/K
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM IMS High Performance Pointer    *
    *                 Checker for z/OS Version 3 Release 1         *
    *                 (FMID=HPC2310).                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: HD Pointer Checker (HDPC) changes       *
    *                      reports to show the disk address higher *
    *                      than 65520 cylinders.                   *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    In order to support Extended Address Volume (EAV), HDPC changes
    reports.
    
    Changed reports of FABPMAIN:
      VALIDPRT data set
      - Validation of a Pointer to a Target at SCAN report
      - Validation of a Pointer to a Target at CHECK report
      - Scan of HISAM Database report
      - Scan of Index Database report
      - Legend for Scan and Validation report
      - Legend for CHECK process Validation report
    
    Changed reports of FABPCHRO:
      PRT data set
      - Control Card and Pointer Information report
    
    The following two major changes are made to the reports:
    1)
    Before change: The format is "CCCCHHHHRR".
      This is a 10-digit hexadecimal number. CCCC is the cylinder,
      HHHH is the track, and RR is the record number.
    After change: The format is "cccCCCCHRR".
      cccCCCC is the cylinder, H is the track, and RR is the record
      number.
    2)
    The display digit of cylinders is increased.
    As this change, the display columns of other items are changed.
    
    For more details, see the documentation changes as below:
    

Problem conclusion

Temporary fix

Comments

  • Documentation Changes:
    Note: The section numbers are those of the BookManager (BKMGR)
    book.
    The documentation is modified as follows:
    ==============================================================
      IMS High Performance Pointer Checker for z/OS, V3R1,
      User's Guide (SC19240100)
    ==============================================================
    >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
    2.0        HD Pointer Checker
    >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
    --------------------------------------------------------------
    Figure 41, 42, and 43 are modifies as follows:
    
    - The digits of CYLS/DEVICE is increased to 9.
    - TRKS/CYLS is displayed from the 63rd column.
    - MAXIMUM BLOCKSIZE is displayed from the 79th column.
    - MAXIMUM TRACK LENGTH is displayed from the 106th column.
    --------------------------------------------------------------
    2.2.3.4.5  Validation of a Pointer to a Target at SCAN
               (HDAM/HIDAM/PHDAM/PHIDAM) report
    --------------------------------------------------------------
    The following descriptions are modified:
    
      VOLUME
        The volume serial number of the device that contains the
        pointer.
    
    | cccCCCCHRR
        The actual direct access address of the record that contains
        the pointer. This is a 10-digit hexadecimal number.
    |   ccc is the high-order 12 bits of the cylinder number.
    |   The value of ccc is printed when the dasd volume is an
    |   Extended Address Volume (EAV). It is padded with blank for
    |   non-EAV volume.
    |   CCCC is the low-order 16 bits of the cylinder number.
    |   H is the track number.
    |   RR is the record number.
    
    Figure 45. is modified as follows:
    
    - The digits of CYLS/DEVICE is increased to 9.
    - TRKS/CYLS is displayed from the 63rd column.
    - MAXIMUM BLOCKSIZE is displayed from the 79th column.
    - MAXIMUM TRACK LENGTH is displayed from the 106th column.
    
      CCCCHHHHRR is changed to cccCCCCHRR.
      For example,
        Before change ==> After Change
        CCCCHHHHRR        cccCCCCHRR
        02BE000213           02BE213
    --------------------------------------------------------------
    2.2.3.4.6  Legend for Scan and Validation report
    --------------------------------------------------------------
    Figure 46. is modified as follows:
    
      DISK ADDRESS OF POINTER:
        BLOCK# . BLOCK CONTAINING POINTER
        VOLUME . DIRECT ACCESS VOLUME ID
    |   cccCCCCHRR OFST .. DASD ADDRESS OF POINTER (IF YOU REFER OR
    |                      CHANGE THE DATABASE CONTENTS BY AMASPZAP,
    |                      CONVERT THE VALUE FORM THE cccCCCCHRR
    |                      FORMAT INTO THE CCCCHHHHRR FORMAT.)
    --------------------------------------------------------------
    2.2.3.4.8  Validation of a Pointer to a Target at CHECK report
    --------------------------------------------------------------
    The following descriptions are modified:
    
      VOLUME
        The volume serial number of the device that contains the
        pointer.
    
    | cccCCCCHRR
        The actual direct access address of the record that contains
        the pointer. This is a 10-digit hexadecimal number.
    |   ccc is the high-order 12 bits of the cylinder number.
    |   The value of ccc is printed when the dasd volume is an
    |   Extended Address Volume (EAV). It is padded with blank for
    |   non-EAV volume.
    |   CCCC is the low-order 16 bits of the cylinder number.
    |   H is the track number.
    |   RR is the record number.
    
    Figure 48. is modified as follows:
    
      CCCCHHHHRR is changed to cccCCCCHRR.
      For example,
        Before change ==> After Change
        CCCCHHHHRR        cccCCCCHRR
        02BE000213           02BE213
    --------------------------------------------------------------
    2.2.3.4.9  Legend for Check Process Validation report
    --------------------------------------------------------------
    Figure 49. is modified as follows:
    
      VOLUME .. DIRECT ACCESS VOLUME ID
    | cccCCCCHRR OFST .. ADDR OF PTR IN ERROR (IF YOU REFER OR
    |                    CHANGE THE DATABASE CONTENTS BY AMASPZAP,
    |                    CONVERT THE VALUE FORM THE cccCCCCHRR FORMA
    |                    INTO TO THE CCCCHHHHRR FORMAT.)
    --------------------------------------------------------------
    2.3        Operating instructions for Disk Address Analyzer
    2.3.3      Output
    2.3.3.1    FABPCHRO PRT data set
    2.3.3.1.3  Control Card and Pointer Information report
    --------------------------------------------------------------
    The following descriptions are modified:
    
      VOLUME
        The volume serial number of the device that contains the
        target relative byte address.
    
    | cccCCCCHRR
        The actual direct access address of the record that contains
        the target relative byte address. This is 10-digit
        hexadecimal number.
    |   ccc is the high-order 12 bits of the cylinder number.
    |   The value of ccc is printed when the dasd volume is an
    |   Extended Address Volume (EAV). It is padded with blank for
    |   non-EAV volume.
    |   CCCC is the low-order 16 bits of the cylinder number.
    |   H is the track number.
    |   RR is the record number.
    
    :
    :
    
      The following fields pertain to the summary of data set
      extents:
    
      VOLSER
        The volume serial number of the devise that contains an
        extent of the input database data set.
    
    | LOW-cccCCCCH
        The lowest cylinder and track on the extent described by
        this report line.
    
    | HIGH-cccCCCCH
        The highest cylinder and track on the extent described by
        this report line.
    >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
    5.0        Space monitor
    >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
    --------------------------------------------------------------
    5.1        Overview of Space monitor
    5.1.5      Restrictions and considerations
    --------------------------------------------------------------
    The following description is added:
    
      - The Indirect List Data Set (ILDS) of HALDB must be monitored
        as a non-IMS data set, leave the DB name and DD name columns
        in the Space Monitor control statement blank.
    
    | - A database data set created on Extended Address Volume (EAV)
    |   is not supported by Space monitor.
    

APAR Information

  • APAR number

    PK73041

  • Reported component name

    IMS POINTER CHE

  • Reported component ID

    5655E0900

  • Reported release

    310

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-09-30

  • Closed date

    2009-04-28

  • Last modified date

    2012-02-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK46126

Modules/Macros

  • FABPCHRO FABPDVC  FABPPEXT FABPRDEF FABPUADR
    FABPXTTB
    

Publications Referenced
SC19240100    

Fix information

  • Fixed component name

    IMS POINTER CHE

  • Fixed component ID

    5655E0900

Applicable component levels

  • R310 PSY UK46126

       UP09/05/01 P F904

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89G","label":"IMS HP Pointer Checker"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
17 February 2012