  • Abend U3700 received along with MSGFABC3794E when running High
    Performance Fast Path Unload.  Error message text is:
      FABC3794E - INVALID "BLOCK TYPE ID" DETECTED IN AREA nn
      (AREANAME:nnnnnnnn)
      FABC3794E     - VALUE EXPECTED: X"08" ("IOVF" CI)
      FABC3794E     - VALUE FOUND   : X"00"
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All DEDB Unload/Reload users of              *
    *                 High Performance Fast Path Utilities         *
    *                 FP Basic Tools Version 2 Release 2           *
    *                 (FMID: H31A220).                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: DEDB UNLOAD (FABCUR1) got U3700 ABEND   *
    *                      with FABC3794E message.                 *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    DEDB UNLOAD (FABCUR1) with RMODTYPE=S and SDEP=PHYSICAL options
    got U3700 ABEND with FABC3794E message.
    FABC3794E message is as follows:
    FABC3794E - INVALID "BLOCK TYPE ID" DETECTED IN AREA nn
                (AREANAME: nnnnnnnn)
                - VALUE EXPECTED: X"08" ("IOVF" CI)
                - VALUE FOUND   : X"00"
    

Problem conclusion

  • When DEDB UNLOAD (FABCUR1) with RMODTYPE=S and SDEP=PHYSICAL
    options attempted to write the area information record (AIR) for
    the area to be reloaded immediately after reading 2nd CI,
    in order to take a lock with the UNLOAD sub-task of other areas,
    FABCUR1U (unload sub-task) set the address of its work area
    (UCT) to the output control table (OCT).
    Since FABCUR1 with above-mentioned options did not have the
    logic to load the OCT address, as a result, the address
    of its UCT was set incorrectly to the address of IOVF CI buffer
    field (UCIB@BFR) at the IOVF buffer header table (IBH) + x'290'
    offset instead of OCT.
    While unloading a segment on the IOVF CI, when FABCUR1U referred
    the address of the IOVF CI buffer, which was a incorrect one,
    detected incorrectly that the IOVF block type (DBLKBTID) is
    wrong.
    
    The macro UR1WSTG0 has been modified to add the flag to indicate
    the area name mismatch between OLDACB and NEWACB when
    SDEP=PHYSICAL option.
    The module FABC1INI has been modified to add the validation
    of the area name between OLDACB and NEWACB when SDEP=PHYSICAL
    option.
    The module FABCUR1U has been modified to load the OCT address
    correctly to write the AIR to USR file.
    
    -------------------------------------------------------------
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    The IMS High Performance Fast Path Utilities for z/OS User's
    Guide Volume 2: Fast Path Basic Tools Version 2 Release 2
    (SC18-9238-02) should be added and changed as follows:
    
       FABC3788E SDEP=PHYSICAL SPECIFIED BUT
                 - CI SIZE UNMATCH BETWEEN OLDACB AND NEWACB
                 - RANDOMIZER RMODTYPE=G SPECIFIED/ASSUMED
     |           - AREA NAME SPECIFIED IN OLDACB NOT FOUND IN NEWACB
    
       Explanation: Program FABCUR1 found that the SDEP=PHYSICAL
          keyword parameter is specified, but
     |    . the CI size of an area does not match between OLDACB
     |      and NEWACB
          . the REORG keyword is not specified or NEWACB DD is
            provided with or without the HIERCHNG= keyword
            parameter.
     |    . the area name defined in the OLDACB was not found
     |      in the NEWACB
    
       System action: FABCUR1 terminates with an abend code of 3788.
     | Programmer response: Correct the error, and rerun the job.
    220Y
    FABCUR1U
    FABC1INI
    UR1WSTG0
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK69887

  • Reported component name

    IMS HP FP UTILI

  • Reported component ID

    5655K9400

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-07-30

  • Closed date

    2008-08-05

  • Last modified date

    2008-09-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PK69922 PK70087 UK38733

Modules/Macros

  •    FABCUR1U FABC1INI UR1WSTG0
    

Publications Referenced
SC18923802    

Fix information

  • Fixed component name

    IMS HP FP UTILI

  • Fixed component ID

    5655K9400

Applicable component levels

  • R220 PSY UK38733

       UP08/08/07 P F808