A fix is available
APAR status
Closed as program error.
Error description
IEW2609W 5104 SECTION FABJXRDS USABILITY ATTRIBUTE OF REUSABLE CONFLICTS WITH REENTRANT was received when applying UK20940. The following message was also received for each module in lmod FABJDPSA: LINK-EDIT PROCESSING FAILED FOR MODULE FABJBUF1 IN LMOD FABJDPSA IN THE SHPSLMD0 LIBRARY. THE RETURN CODE WAS 04. THE SEQUENCE NUMBER WAS 000012.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy * * for z/OS version 4 users (FMID=H1J0410) * **************************************************************** * PROBLEM DESCRIPTION: When you apply the maintenance of * * FABJXRDS, link process of FABJDPSn * * terminates RC 04. Because FABJXRDS * * attribute conflicts with FABJDPSn. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When you apply the maintenance of FABJXRDS, link process of FABJDPSn terminates RC 04. Because FABJXRDS attribute conflicts with FABJDPSn. FABJXRDDS in FABJDPSn is not called any process and this complication can not affect to process. But after modules are included in load module, it can not be removed. So HPIC set to igonre RC=04 in link process of FABJXRDS.
Problem conclusion
FABJXRDS has been reassembled. JCLIN for FABJDPSn has been modified that allow RC 04 in link process.
Temporary fix
Comments
APAR Information
APAR number
PK68272
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-06-26
Closed date
2008-09-05
Last modified date
2008-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK39572
Modules/Macros
FABJXRDS H1J0410J
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R410 PSY UK39572
UP08/09/12 P F809
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89E","label":"IMS HP Image Copy"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1.0"}]
Document Information
Modified date: