IBM Support

PK68262: High CPU consumption in conjunction with high storage usage when running near term history due to large data chains

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • KO2O1421E NEAR-TERM HISTORY DATA COLLECTOR - WORKLOAD DANALYZE
    HAD
    LOOPED MORE THAN TEN TIMES. TERMINATING (SERVLOOP)
    
    Thread token being used to match IFCID records is unsuccessful
    for distserv threads in an environment where ACCUMACC is other
    than NO.
    
    Other circumstances can result in large volumes of data being
    left on the chain - this can manifest itself as
    increasing storage utilization
    increasing CPU consumption
    
    KO2O1310I NEAR-TERM HISTORY DATA COLLECTOR SERVER KO2ISRVB HAS
    TERMINATED (SVESTAE )
    CI0970: OMEGAMON SUBTASK ABEND CODE=04C78000
    PSW=070C00008142E8AA  TCB=00A81988
    CI0971: PROGRAM NAME=KO2ISRVB
    KO2O1307I NEAR-TERM HISTORY DATA COLLECTOR IS TERMINATING
    (H2INITE )
    
    OMEGAMON:   >> OB0925: Loop in OMEGAMON Base <<
    OMEGAMON:  OB0933 OMEGAMON resource cleanup initiated for abend
    U0925 RC=00000000
    OMEGAMON:  OB0935 OMEGAMON resource cleanup complete
    
    ABENDC78 SC78 C78 HISTORICAL
    ABEND878 S878 878
    ABENDA78 SA78 A78
    insufficient storage shortage
    
    Also watch for messages:
    KO2O0555I NEAR-TERM HISTORY DATA COLLECTOR - A BATCH JOB IS
    SUBMITTED TO
    FLUSH THE CONTENTS OF THE H2 DATA SET
    KO2R0133I CAPTURE DATA SET IS REUSABLE -
    OLDB.DB2.OMVINT.SY34.DI1A.RKD2VS01
    KO2O1313W NEAR-TERM HISTORY DATA COLLECTOR SUSPENDED DATA
    OLLECTION. NO
    AVAILABLE STORAGE DB2=DI1A (OUTBUFR )
    KO2O1314I NEAR-TERM HISTORY DATA COLLECTOR RESUMED DATA
    COLLECTION. STORAGE AVAILABLE DB2=DI1A (OUTBUFR )
    

Local fix

  • SET ACCUMACC=NO in DSNZPARM
    
    This setting will result in a significant increase in the volume
    of trace records being created. This can increase the SMF file
    volume if DB2 trace data is being collected to SMF.
    
    Also consider cycling the historical task every couple of hours
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Common Collector                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Large chains of IFCID accounting data   *
    *                      building up in storage over time.       *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    Problem matching accounting data to package accounting data.
    Unmatched data was building up in storage until available memory
    is used up, or the historical collector exceeded CPU limit.
    
    PROBLEM CONCLUSION:
    Allow more tolerance in matching timestamps.  Assure all
    matching information is collected.  Assure that old unmatched
    data is cleaned in a timely manner.  Correct code point which
    was failing to output the accounting data.
    

Problem conclusion

  • Allow more tolerance in matching timestamps.  Assure all
    matching information is collected.  Assure that old unmatched
    data is cleaned in a timely manner.  Correct code point which
    was failing to output the accounting data.
    
    
    KEYWORDS : IFCID ACCOUNTING DATA MEMORY
               HISTORICAL COLLECTOR EXCEEDED CPU LIMIT
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PK68262

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-06-26

  • Closed date

    2008-07-04

  • Last modified date

    2008-08-11

  • APAR is sysrouted FROM one or more of the following:

    PK62643

  • APAR is sysrouted TO one or more of the following:

    UK37875

Modules/Macros

  • KO2ACAPS KO2ACAP2 KO2CDSCB KO2CMVSC KO2CMVSF
    KO2CNADB KO2CNASB KO2CNSRB KO2CNTPS KO2CNTP2 KO2DAUDS KO2DAUD2
    KO2DBCIB KO2DCS2B KO2DDSBS KO2DDSB2 KO2DMSCS KO2DMSC2 KO2DTHDS
    KO2DTHD2 KO2DXSTB KO2DXS1S KO2DXS12 KO2DXS2S KO2DXS22 KO2HDTIB
    KO2HDTPB KO2HINTB KO2HMSGB KO2HPRCB KO2HPR1B KO2HPR2B KO2HSQIB
    KO2HSQPB KO2HSVPB KO2HTRMB KO2HVINB KO2HWLMB KO2ICOLS KO2ICOL2
    KO2IINTB KO2LCAPB KO2MI00B KO2MSBDB KO2MSB1B KO2MSB2B KO2MSB3B
    KO2MSB4B KO2MSUMB KO2OH2IB KO2OMGCB KO2ONTAB KO2OTHDB KO2OTHLB
    KO2OZM2B KO2SACS  KO2SAU1  KO2SAU2  KO2SAU3  KO2SAU4  KO2SAU6
    KO2SAU7  KO2SSUB  KO2SSUM  KO2TSB1B KO2TSB2B KO2TSB3B KO2TSB4B
    KO2WGETB KO2XLKDS KO2XLKD2
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R310 PSY UK37875

       UP08/07/08 P F807

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
11 August 2008