IBM Support

PK67952: WRONG LENGTH FOR MODULE CQM#CQMA LOADED INTO LPA

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Wrong length for module CQM#SDIR loaded into LPA
    
    This APAR changed code to obtain correct length for module
    CQM#CQMA loaded into LPA, and also will not load CQM#CQMA and
    CQM#CQMI dynamically into the LPA at startup, if they are
    already statically loaded into the LPA.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Query Monitor.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Wrong length for module CQM#SDIR        *
    *                      loaded into LPA.                        *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK67952

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    230

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-06-20

  • Closed date

    2008-08-04

  • Last modified date

    2008-09-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK38655

Modules/Macros

  •    CQM$MAIN CQM#BCMX CQM#INTX CQM#MSSN CQM#SDIR
    CQM#SSMN
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R230 PSY UK38655

       UP08/08/13 P F808

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"230","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
09 August 2024