Error description

  • ABENDS0C1 occurred in FABHA30.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS High Performance Unload for *
    *                 z/OS, Version 1 Release 1 (FMID=H1IN110).    *
    ****************************************************************
    * PROBLEM DESCRIPTION: After an I/O error of OSAM database,    *
    *                      HP UNLOAD receives ABEND0C1 in FABHA30. *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    After an I/O error of OSAM database, HP UNLOAD receives ABEND0C1
    in FABHA30. On return from SYNADAF, the high order byte of
    register 15 has been modified, but register 15 is incorrectly
    used as a base register in the SYNAD routine for OSAM dataset.
    ABEND0C4 and ABEND0C2 may occur depending on what data is
    in memory accessed by the incorrect 31 bit mode address.
    

Problem conclusion

  • The module FABHA30 has been modified not to use register 15 as
    a base register in SYNAD routine.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK67799

  • Reported component name

    IMS HIGHPERF UN

  • Reported component ID

    5655E0600

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-06-18

  • Closed date

    2008-06-26

  • Last modified date

    2008-07-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK37711

Modules/Macros

  •    FABHA30
    

Fix information

  • Fixed component name

    IMS HIGHPERF UN

  • Fixed component ID

    5655E0600

Applicable component levels

  • R110 PSY UK37711

       UP08/06/28 P F806

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSCX89K","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"110"}]

Document Information

Modified date:
20 October 2020