Error description
Dump Title: D2D0,ABND=0C4-00000011,U=LS2@ ,M=(N),C=810.DMC -DSNKSALO,M=DSNTFRCV,PSW=070C2000AFF92582,A=00F8 ABEND0C4-11 CQMOXG81+2582 (PK51565) on a D505 5000 C562 (CLC) instruction with R5 being bad. This ABEND is similar to the ABEND0C4 reported in PK51565 with FRR PARAMETER AREA of zeros. Also ABEND0C4-10 CQMOXG81+2576 (PK51565) on a E35050180017 LLGT instruction, again with R5 bad.
Local fix
Turn off object collection by adding OBJECTS(N) to the CQMPARMS file and cycling the collector
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Query Monitor. * **************************************************************** * PROBLEM DESCRIPTION: Dump Title: D2D0,ABND=0C4-00000011, * * U=LS2@ ,M=(N),C=810.DMC * * -DSNKSALO,M=DSNTFRCV, * * PSW=070C2000AFF92582,A=00F8 * * ABEND0C4-11 CQMOXG81+2582 (PK51565) on * * a D505 5000 C562 (CLC) instruction * * with R5 being bad. This ABEND is * * similar to the ABEND0C4 reported in * * PK51565 with FRR PARAMETER AREA of * * zeros. Also ABEND0C4-10 CQMOXG81+2576 * * (PK51565) on a E35050180017 LLGT * * instruction, again with R5 bad. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PK67287
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-06-06
Closed date
2008-07-31
Last modified date
2008-09-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK38630 UK38631
Modules/Macros
CQMOXGET CQMOXG81 CQMOXG91
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.