IBM Support

PK67214: KO2E3066S RC=1001 PERSISTS AFTER PK52874=PK53416/UK35165 and HIGH ECSA USAGE S878 WITH OBJECT ANALYSIS ONLY

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • KO2E3066S RC=1001 PERSISTS AFTER PK52874=PK53416/UK35165
    
    * Subpool 241, Key 7  Total Alloc:  BAA2000        SP241
    Of this there are 1753 allocations of X'1B000' bytes with many
    of them related to storage that looks like the following:
                  | ...........  *** |
                  |  COPYRIGHT (C) 1 |
                  | 977,1988 - 2006  |
                  | IBM CORPORATION  |
                  | *** ....O2EIX1   |
                  |  V41051003/27/08 |
    FYI.
    KO2E3070I DT05 OBJECT ANALYSIS INITIALIZATION IN PROGRESS
    KO2E3066S DT05 OBJECT ANALYSIS INITIALIZATION FAILED, REASON
                   CODE=1001
    KO2E3064I DT05 OBJECT ANALYSIS TERMINATION SUCCESSFUL
    The above messages can be seen issued many time.  The storage
    shows up under *SYSTEM* in the IPCS VSMDATA report, both below
    and above the line (CSA/ECSA):
     0000 *SYSTEM* ........ Ac C 00BECD28 0001A2D8 0D953596
     0000 *SYSTEM* ........ Ac C 00C07D28 0001A2D8 0D953596
     0000 *SYSTEM* ........ Ac C 0F96B798 0000E868 0D95319A
    Also possible is running out of CSA as seen in this SVC DUMP:
     Dump Title: COMPON=VSM,COMPID=SC1CH,ISSUER=IGVVSERR,OUT_OF_CSA
    for an ABEND878 rc08.
    Keyword:
    ICYEXIT O2EIX1
    

Local fix

  • You can turn off Object Analysis using the following command:
    /F cccccccc,F EVENTMGR,STOP DB2=(db2ssid1,db2ssid2,...db2ssidn)
    or
    /F cccccccc,P EVENTMGR  where ccccc is your server started task.
    (volume analysis)
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   OMEGAMON collector                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: If Object Analysis fails to initialize, *
    *                      it can repetitively allocate ECSA until *
    *                      ECSA is exhausted, causing S878 abends  *
    *                      and eventually a system outage.  The    *
    *                      problem has only been detected          *
    *                      occasionally when a DB2 system recycles *
    *                      while Object Analysis is operating for  *
    *                      that DB2 system.                        *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    Object Analysis was not always freeing the ECSA it obtained, if
    it failed to initialize.
    
    PROBLEM CONCLUSION:
    Always free ECSA when Object Analysis fails to initialize.
    

Problem conclusion

  • Always free ECSA when Object Analysis fails to initialize.
    
    KEYWORDS : ECSA  OBJECT ANALYSIS
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PK67214

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-06-05

  • Closed date

    2008-10-08

  • Last modified date

    2017-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK40545

Modules/Macros

  •    KO2EOJSA KO2EOJSS KO2EOJS2
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK40545

       UP08/10/10 P F810 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410"}]

Document Information

Modified date: