A fix is available
APAR status
Closed as program error.
Error description
KO2E3066S RC=1001 PERSISTS AFTER PK52874=PK53416/UK35165 * Subpool 241, Key 7 Total Alloc: BAA2000 SP241 Of this there are 1753 allocations of X'1B000' bytes with many of them related to storage that looks like the following: | ........... *** | | COPYRIGHT (C) 1 | | 977,1988 - 2006 | | IBM CORPORATION | | *** ....O2EIX1 | | V41051003/27/08 | FYI. KO2E3070I DT05 OBJECT ANALYSIS INITIALIZATION IN PROGRESS KO2E3066S DT05 OBJECT ANALYSIS INITIALIZATION FAILED, REASON CODE=1001 KO2E3064I DT05 OBJECT ANALYSIS TERMINATION SUCCESSFUL The above messages can be seen issued many time. The storage shows up under *SYSTEM* in the IPCS VSMDATA report, both below and above the line (CSA/ECSA): 0000 *SYSTEM* ........ Ac C 00BECD28 0001A2D8 0D953596 0000 *SYSTEM* ........ Ac C 00C07D28 0001A2D8 0D953596 0000 *SYSTEM* ........ Ac C 0F96B798 0000E868 0D95319A Also possible is running out of CSA as seen in this SVC DUMP: Dump Title: COMPON=VSM,COMPID=SC1CH,ISSUER=IGVVSERR,OUT_OF_CSA for an ABEND878 rc08. Keyword: ICYEXIT O2EIX1
Local fix
You can turn off Object Analysis using the following command: /F cccccccc,F EVENTMGR,STOP DB2=(db2ssid1,db2ssid2,...db2ssidn) or /F cccccccc,P EVENTMGR where ccccc is your server started task. (volume analysis)
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - OMEGAMON collector * **************************************************************** * PROBLEM DESCRIPTION: If Object Analysis fails to initialize, * * it can repetitively allocate ECSA until * * ECSA is exhausted, causing S878 abends * * and eventually a system outage. The * * problem has only been detected * * occasionally when a DB2 system recycles * * while Object Analysis is operating for * * that DB2 system. * * * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Object Analysis was not always freeing the ECSA it obtained, if it failed to initialize. PROBLEM CONCLUSION: Always free ECSA when Object Analysis fails to initialize.
Problem conclusion
Always free ECSA when Object Analysis fails to initialize. KEYWORDS : ECSA OBJECT ANALYSIS
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PK67214
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-06-05
Closed date
2008-10-08
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK40545
Modules/Macros
KO2EOJSA KO2EOJSS KO2EOJS2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK40545
UP08/10/10 P F810
Fix is available