IBM Support

PK66994: PROVIDE DEFAULT DFSMSCE0 PROGRAM SO THAT IMS V8, V9 AND V10 RECOGNIZES WLR'S PRESENCE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If the WLR user does not provide the DFSMSCE0 MSC User exit (IMS
    V8, V9 and V10) - or any of the DFSMCTR0, DFSNPRT0 or DFSCMPR0
    exits (IMS V8 and IMS V9 only) - IMS WLR will appear to
    initialize correctly during IMS start-up, but the WLR code will
    never be executed as IMS will not recognize that WLR is active
    without one of these exits. Attempts to turn the product TRACE
    ON will result in the WLR Control blocks being set correctly,
    though no trace records will ever be produced.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of Workload Router V2R5.           *
    ****************************************************************
    * PROBLEM DESCRIPTION: Provide default DFSMSCE0 program so     *
    *                      that IMS V8, V9 and V10 recognize       *
    *                      WLR's presence.                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Provide default DFSMSCE0 program so that IMS V8, V9 and V10
    recognize WLR's presence. If the WLR user does not provide
    the DFSMSCE0 MSC User exit (IMS V8, V9 and V10) - or any of
    the DFSMCTR0, DFSNPRT0 or DFSCMPR0 exits (IMS V8 and IMS V9
    only) - IMS WLR will appear to initialize correctly during
    IMS start-up, but the WLR code will never be executed as IMS
    will not recognize that WLR is active without one of these
    exits. Attempts to turn the product TRACE ON will result in
    the WLR Control blocks being set correctly, though no trace
    records will ever be produced.
    

Problem conclusion

  • New module IWXMSCE0 has been created to ensure that IMS
    recognizes WLR's presence in this situation.
    After applying this APAR/PTF, IMS needs to be stopped and
    restarted (WARM start is sufficient)
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK66994

  • Reported component name

    IMS WLR

  • Reported component ID

    5697B8700

  • Reported release

    250

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-06-02

  • Closed date

    2008-06-17

  • Last modified date

    2008-07-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    H23J250J H23J251J H23J253J IWXMSCE0
    

Fix information

  • Fixed component name

    IMS WLR

  • Fixed component ID

    5697B8700

Applicable component levels

  • R250 PSY UK37429

       UP08/06/21 P F806

  • R251 PSY UK37430

       UP08/06/21 P F806

  • R253 PSY UK37431

       UP08/06/20 P F806

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSCX8AD","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.5.0"}]

Document Information

Modified date: