Error description
The Data Collector, on a default install, runs with the trace log at DEBUG_MIN level. This can cause a really serious performance hit, especially on Portal Server. This occurs on all platforms, all operating systems, etc. There are no log files to upload. %dc_home%/toolkit/etc/cynlogging.properties should have all instances of "DEBUG_MIN" changed to "INFO". On the IBM internal portal server where I tested this today, threads queued up with 30-second response times waiting for a chance to write ITCAM log file entries. With the log setting set to INFO, response times were sub-second.
Local fix
Problem summary
THE DATA COLLECTOR, ON A DEFAULT INSTALL, RUNS WITH THE TRACE LOG AT DEBUG_MIN LEVEL.
Problem conclusion
This is fixed in FP4
Temporary fix
Comments
APAR Information
APAR number
PK66656
Reported component name
ITCAM WAS DIST
Reported component ID
5724L6200
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-05-27
Closed date
2009-01-21
Last modified date
2009-01-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITCAM WAS DIST
Fixed component ID
5724L6200
Applicable component levels
R610 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS3PGL","label":"Tivoli Composite Application Manager for WebSphere"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
23 October 2021