Error description
VIC=Y results in DFS301A or FABJ0177E. This occurs because the VIC function uses an incorrect length for the DBD name field and thus uses an incorrect DB name.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 4 Release 1 users ( FMID=H1J0410 ) * **************************************************************** * PROBLEM DESCRIPTION: HPIC Image Copy function can not treat * * correctly the DBD name of the index * * database that is searched by IDXSRCH=Y * * when the length of the DBD name that is * * used to search the index database is * * shorter than the DBD name of the * * searched index database. * * * * Also, this APAR fixes the problems to * * occur when DBALL=Y is specified in * * ICEIN control statement. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HPIC Image Copy function can not treat correctly the DBD name of the index database that is searched by IDXSRCH=Y when the length of the DBD name that is used to search the index database is shorter than the DBD name of the searched index database. The cause of this problem is that the length of the DBD name of the database specified in ICEIN is incorrectly used for processing the searched index database. Depending on how the database data set is allocated, the results of HPIC Image Copy function differs as follows: - HPIC terminates with RC=08 and message IEC130I ( MSGIEC130I ) for OPEN macro to the searched index database when one of the following conditions is satisfied: - The database specified in ICEIN and the searched index database are allocated dynamically. - The database specified in ICEIN is allocated by JCL DD and the searched index database is allocated dynamically. - HPIC terminates with RC=08 and message FABJ0177E ( MSGFABJ0177E ) for NOTIFY.UIC command to the searched index database when one of the following conditions is satisfied: - The database specified in ICEIN and the searched index database are allocated by JCL DD. - The database specified in ICEIN is allocated dynamically and the searched index database is allocated by JCL DD. Also, this APAR fixes the following problems to occur when DBALL=Y is specified in ICEIN control statement: - &GDG as symbolic variable is not applied to the image copy data set name of the searched database when following conditions are satisfied; - The database specified in ICEIN is an index database. - VIC=Y or HDPC=O is specified. - The image copy data set of the database registered as recoverable is not created when following conditions are satisfied; - HPIC Concurrent Image Copy function is used. - The database specified in ICEIN is registered as non- recoverable in DBRC.
Problem conclusion
FABJIDXN has been modified as follows: - To set the correct length of the DBD name for the searched index database. - To check whether the searched index database is allocated by DD card in the JCL. - To clear the HPIC control block information that is inherited from the database specified in ICEIN. FABJDBAL has been modified to clear the HPIC control block information that is inherited from the database specified in ICEIN. The following modules have been reassembled. FABJIDX7 FABJIDX8 FABJIDX9 FABJIDXA
Temporary fix
Comments
APAR Information
APAR number
PK66570
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-05-23
Closed date
2008-06-09
Last modified date
2008-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK37169
Modules/Macros
FABJDBAL FABJIDXA FABJIDXN FABJIDX7 FABJIDX8 FABJIDX9
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R410 PSY UK37169
UP08/06/11 P F806
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.1.0","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 December 2020