Error description

  • User experienced a hang/loop condition when running OMPE
    classical interface.  The SERVER log shows
    OMEGAMON:   >> OB0925: Loop in OMEGAMON Base <<
    OMEGAMON:  OB0933 OMEGAMON resource cleanup initiated for abend
                      U0925 RC=00000000
    OMEGAMON:  OB0935 OMEGAMON resource cleanup complete
    KO2O0452I TERMINATING COMMON SERVICES
    .
    Analysis from the INSPECT report shows the loop is occuring
    in code related to translating the DBID.
    .
    hang/loop condition in DBID translation process.
    From SYSTRACE:
     02D8 00782E88  DSP        077D8001 91D851D4
     02D8 00782E88  EXT   1005 077DA001 91D851CA
     02D8 00782E88  DSP        077DA001 91D851CA
     02D8 00782E88  EXT   1005 077D9001 91D85212
     02D8 00782E88  DSP        077D9001 91D85212
     02D8 00782E88  EXT   1005 077D8001 91D851F0
    with CSECT KO2XLKDA (at PK59371 level) starting at 11D84E40.
    This is code dealing with DB2 DBDs.  TCB 00782E88 in this case
    is using by far the most CPU.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - OMEGAMON Server                            *
    *                 - Common Collector                           *
    *                 - Classic Interface                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: LOOP IN DBID TRANSLATION FOR DB2 V910.  *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    INCORRECT VALUE USED FOR DETECTION OF END-OF-CHAIN CONDITION.
    
    PROBLEM CONCLUSION:
    CORRECTLY DETECT THE END-OF-CHAIN CONDITION
    
    KEYWORDS: LOOP DBID DB2-V910
    

Problem conclusion

  • CORRECTLY DETECT THE END-OF-CHAIN CONDITION
    
    KEYWORDS: LOOP DBID DB2-V910
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK66453

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-05-21

  • Closed date

    2008-05-23

  • Last modified date

    2017-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK36736

Modules/Macros

  •    KO2XLKDA KO2XLKDS KO2XLKD2
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK36736

       UP08/05/28 P F805

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]