IBM Support

PK65009: OCCURS WHEN BTS PUTS THE LOB TYPE DATA ON BTSOUT.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND0C4 occurs when BTS puts the LOB type data on BTSOUT.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: BTS V3 USERS WITH DB2                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND0C4 OCCURS WHEN BTS PUTS THE LOB   *
    *                      TYPE DATA ON BTSOUT.                    *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    ABEND0C4 occurs or garbage is shown on the DATA=, when BTS puts
    the LOB type data on BTSOUT.
    The reason is because BTS did not have the correct data address.
    

Problem conclusion

  • BTS is modified to have the correct data addres when putting the
    LOB type data on the BTSOUT.
    
    The IMS BTS User's Guide and Reference ( SC18-7149-01 )
    will be updated with following changes:
    
    << 4.2.4 ./O Command >>
    
      < Change ./O SQLOBLN= >
    
    Specifies the length of output data that is of LOB data type
    (large objects data type) that the customer would like to put
    on the BTSOUT or the TSO terminal display. The length of LOB
    data type in SQLDA returned by DB2 is always 0. If this
    parameter is not specified, the LEN= operand on the BTSOUT shows
    0 and LOB data is not put on the BTSOUT or the TSO terminal
    display.
    
    If the length defined in the applicaiotn program is smaller
    than SQLOBLN=nn, BTS substitutes the actual data length for nn.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK65009

  • Reported component name

    IMS BTS

  • Reported component ID

    5655A1400

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-04-24

  • Closed date

    2008-05-07

  • Last modified date

    2008-06-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK36237

Modules/Macros

  •    BTSSVAR0
    

Publications Referenced
SC18714901    

Fix information

  • Fixed component name

    IMS BTS

  • Fixed component ID

    5655A1400

Applicable component levels

  • R310 PSY UK36237

       UP08/05/09 P F805

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY2","label":"IMS Batch Terminal Simulator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]

Document Information

Modified date:
20 October 2020