A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4 occurs when BTS puts the LOB type data on BTSOUT.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: BTS V3 USERS WITH DB2 * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 OCCURS WHEN BTS PUTS THE LOB * * TYPE DATA ON BTSOUT. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** ABEND0C4 occurs or garbage is shown on the DATA=, when BTS puts the LOB type data on BTSOUT. The reason is because BTS did not have the correct data address.
Problem conclusion
BTS is modified to have the correct data addres when putting the LOB type data on the BTSOUT. The IMS BTS User's Guide and Reference ( SC18-7149-01 ) will be updated with following changes: << 4.2.4 ./O Command >> < Change ./O SQLOBLN= > Specifies the length of output data that is of LOB data type (large objects data type) that the customer would like to put on the BTSOUT or the TSO terminal display. The length of LOB data type in SQLDA returned by DB2 is always 0. If this parameter is not specified, the LEN= operand on the BTSOUT shows 0 and LOB data is not put on the BTSOUT or the TSO terminal display. If the length defined in the applicaiotn program is smaller than SQLOBLN=nn, BTS substitutes the actual data length for nn.
Temporary fix
Comments
APAR Information
APAR number
PK65009
Reported component name
IMS BTS
Reported component ID
5655A1400
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-04-24
Closed date
2008-05-07
Last modified date
2008-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK36237
Modules/Macros
BTSSVAR0
| SC18714901 |
Fix information
Fixed component name
IMS BTS
Fixed component ID
5655A1400
Applicable component levels
R310 PSY UK36237
UP08/05/09 P F805
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.