APAR status
Closed as program error.
Error description
HPFP Reorganization Reload function can hang when some segments in multiple areas in a DEDB have the PCL pointers. Keywords: Wait Waits Hung Hang Hangs High Performance Fast Path
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of High Performance Fast Path * * Reorganization Tool Version 2 Release 2. * * (FMID: H31A220) * **************************************************************** * PROBLEM DESCRIPTION: HPFP Reorganization Reload function * * can hang when some segments in * * multiple areas in a DEDB have the PCL * * pointers. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HPFP Reorganization Reload function can hang or cause some pointer errors when one thread subtask processes multiple areas that have the PCL pointers. Because the initialization of the internal work areas after processing one area is insufficient, this problem can occur.
Problem conclusion
The module HFPKARI0 has been modified to clear the internal work areas for new area process. 220Y HFPKARI0
Temporary fix
Comments
APAR Information
APAR number
PK62713
Reported component name
IMS HP FP UTILI
Reported component ID
5655K9400
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-03-13
Closed date
2008-04-11
Last modified date
2008-05-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK35470
Modules/Macros
HFPKARI0
Fix information
Fixed component name
IMS HP FP UTILI
Fixed component ID
5655K9400
Applicable component levels
R220 PSY UK35470
UP08/04/12 P F804