A fix is available
APAR status
Closed as program error.
Error description
Register 8 and Register 0 where not being reset after leaving 64 bit mode processing. The results may be manifested in different ways depending on the code path followed. This will not occur in all cases, but only certain product execution (and indeterminate) paths that lead to register 8 and register 0 having non-zero high word. Fix ensures register 8 and register 0 has zero values in high word when leaving this 64 bit routine.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Log Analysis Tool. * **************************************************************** * PROBLEM DESCRIPTION: Register 8 and Register 0 where not * * being reset after leaving 64 bit mode * * processing. The results may be * * manifested in different ways depending * * on the code path followed. This will * * not occur in all cases, but only * * certain product execution (and * * indeterminate) paths that lead to * * register 8 and register 0 having * * non-zero high word. Fix ensures * * register 8 and register 0 has zero * * values in high word when leaving this * * 64 bit routine. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PK62341
Reported component name
DB2 LOG ANALYSI
Reported component ID
5655E6601
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-03-06
Closed date
2008-03-28
Last modified date
2008-05-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
ALA#MREP
Fix information
Fixed component name
DB2 LOG ANALYSI
Fixed component ID
5655E6601
Applicable component levels
R310 PSY UK35069
UP08/04/04 P F804
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310"}]
Document Information
Modified date:
12 April 2021