IBM Support

PK62158: OC USING WSL UNINITIALIZED VARIABLE IN EXEC ADB2W1 AT LINE 1451.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • OC using WSL Uninitialized variable in exec
    ADB2W1 at line 1451.
    

Local fix

  • APPLY PTF.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Administration Tool using       *
    *                 the Run WSL command.                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: During Run WSL processing a TSO         *
    *                      ALLOCATE command may fail with message: *
    *                      INVALID DATA SET NAME due to a missing  *
    *                      data set name.                          *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    If Run a Change is used residual data is left in the ISPF
    SHARED pool. Run WSL will incorrectly use this residual value
    if the WSL contains parallel jobs. This results in a null value
    being used for the data set name.
    

Problem conclusion

  • The problem has been fixed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK62158

  • Reported component name

    DB2 OBJECT COMP

  • Reported component ID

    5697G6400

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-03-04

  • Closed date

    2008-05-15

  • Last modified date

    2008-06-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    GOCGCMP
    

Fix information

  • Fixed component name

    DB2 OBJECT COMP

  • Fixed component ID

    5697G6400

Applicable component levels

  • R720 PSY UK36526

       UP08/05/30 P F805

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUVH","label":"IBM Db2 Object Comparison Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]