IBM Support

PK62105: ATF CICSTRAN VALUE IS NOT CLEANED OUT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • CICSTRAN value entered for the previous ATF trace(s) is not
    cleaned out when new trace is about to be started.
    
    First trace :
     ===============================================================
    =================
     >                          SPECIFY APPLICATION TRACE
      ATRQ
     +    THE FOLLOWING TRACE REQUEST HAS BEEN SELECTED
     +    PRESS THE ENTER KEY, TO CANCEL THE TRACE REQUEST USE PF3 :
     +
     :
    DSN=____________________________________________DATA SET NAME
     :          TIME=0005    NUMBER OF MINS TO TRACE (0001-9999)
     :         FLUSH=010     NUMBER OF SECONDS BETWEEN VSAM WRITES
     :      PLANNAME=A71GO0   ________ ________ ________ ________
     :                         PLAN NAME(S) OR ALL FOR ALL ACTIVE
    THREADS
     :        AUTHID=________ ________ ________ ________ ________
     :                         DB2 AUTHORIZATION IDENTIFIER(S)
     :       TSOUSER=________TSO USERID (TSO FOREGROUND APP)
     :       JOBNAME=________JOBNAME (TSO BATCH APP)
     :      CICSTRAN=MVON    CICS TRANS ID
     :      CICSCONN=________CICS CONNECTION ID)
     :       PSBNAME=________IMS PSB NAME
     :         IMSID=________IMS ID OF THE IMS REGION
     :      LOCKDATA=N       COLLECT DB2 LOCK TRACE RECS? (Y/N)
     :      SCANDATA=Y       COLLECT DB2 SCAN TRACE RECS? (Y/N)
     :       SQLDATA=Y    COLLECT DB2 SQL  TRACE RECS? (Y/N)
     :      THRDDATA=Y    COLLECT DB2 THREAD TRACE RECS?  (Y/N)
     :      CONNDATA=Y    COLLECT DB2 CONNECT TRACE RECS? (Y/N)
     :           SMF=N    WRITE TRACE DATA TO SMF? (Y/N)
     :           GTF=N    WRITE TRACE DATA TO GTF? (Y/N)
     :       MEMSIZE=08   COLLECTION WORKAREA MEMORY SIZE (01-08
    MEG)
     ===============================================================
    =================
    
    Second trace :
     ===============================================================
    =================
     >                          SPECIFY APPLICATION TRACE
      ATRQ
     + TYPE DB2 PLAN NAME TO BE TRACED. ALSO, PROVIDE ADDITIONAL
    OPTIONAL
     + SELECTION INFORMATION TO LIMIT TRACE OUTPUT. TO SAVE TRACE
    RECORDS
     + FOR LATER VIEWING YOU MUST SPECIFY A DATA SET NAME FOR DSN
     +
     :
    DSN=____________________________________________DATA SET NAME
     :          TIME=0005    NUMBER OF MINS TO TRACE (0001-9999)
     :         FLUSH=010     NUMBER OF SECONDS BETWEEN VSAM WRITES
     :      PLANNAME=A18AO0   ________ ________ ________ ________
     :                         PLAN NAME(S) OR ALL FOR ALL ACTIVE
    THREADS
     :        AUTHID=CICSBAT  ________ ________ ________ ________
     :                         DB2 AUTHORIZATION IDENTIFIER(S)
     :       TSOUSER=________TSO USERID (TSO FOREGROUND APP)
     :       JOBNAME=________JOBNAME (TSO BATCH APP)
    ****************************************************************
     :      CICSTRAN=MVON    CICS TRANS ID                <---WRONG!
    ****************************************************************
     :      CICSCONN=________CICS CONNECTION ID)
     :       PSBNAME=________IMS PSB NAME
     :         IMSID=________IMS ID OF THE IMS REGION
     :      LOCKDATA=N       COLLECT DB2 LOCK TRACE RECS? (Y/N)
     :      SCANDATA=Y       COLLECT DB2 SCAN TRACE RECS? (Y/N)
     :       SQLDATA=Y    COLLECT DB2 SQL  TRACE RECS? (Y/N)
     :      THRDDATA=Y    COLLECT DB2 THREAD TRACE RECS?  (Y/N)
     :      CONNDATA=Y    COLLECT DB2 CONNECT TRACE RECS? (Y/N)
     :           SMF=N    WRITE TRACE DATA TO SMF? (Y/N)
    1===============================================================
    =================
    

Local fix

  • Overtype or clear the value manually
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Classic Interface                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: ATF CICSTRAN VALUE IS NOT CLEANED OUT;  *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    TSOUSER/JOBNAME/CICSTRAN/PSBNAME fields on ZATRQ2 panel do not
    filled / cleaned up as expected when attempt made to start ATF
    trace from Thread Detail ZTDTL panel.
    
    PROBLEM CONCLUSION:
    Code changed to fill in proper field depending on thread type
    and clean up the rest of incompatible fields.
    

Problem conclusion

  • Code changed to fill in proper field depending on thread type
    and clean up the rest of incompatible fields.
    
    KEYWORDS: INCORROUT ZTDTL ZATRQ2 KO2RACFX
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK62105

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-03-04

  • Closed date

    2008-07-17

  • Last modified date

    2017-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK38210 UK38211

Modules/Macros

  •    KO2OTHDB KO2RACFX
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R310 PSY UK38210

       UP08/07/24 P F807

  • R410 PSY UK38211

       UP08/07/24 P F807

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
04 February 2017