IBM Support

PK61164: REPORT SUPPRESSION FOR ONLINE POINTER CHECKER

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • Online Pointer Checker ( OPC ) is being enhanced to suppress
    specified reports.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Online Pointer Checker and Online        *
    *                 Expert Reorganization users of High          *
    *                 Performance Fast Path Utilities FP Online    *
    *                 Tools Version 3 Release 2 (FMID: H31A320).   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Fast Path Online Tools (FPO) supports   *
    *                      UOW REPORT suppression function.        *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR allows FPO to suppress UOW REPORT or to specify UOW
    range of the UOW REPORT.
    This is a FITS requirement MR041207678.
    

Problem conclusion

Temporary fix

Comments

  • ========================
    = DOCUMENTATION CHANGE =
    ========================
    The IMS High Performance Fast Path Utilities for z/OS User's
    Guide Volume 3: Fast Path Online Tools Version 3 Release 2
    (SC18-9871-03).
    
    ----------------------------------------------------------------
    Chapter 4. Using OPC
    
    REPORT statement
    The following lines should be added as follows:
    
      +------------------------------------------------------+
      |             +-----------------------------+          |
      |             |                             |          |
      |>>-- REPORT --------------------------------------><- |
      |             |                             |          |
      |             +- REPORTDD=-+- FPXRPTS -+----+          |
      |             |            +- ddname --+    |          |
    | |             |                             |          |
    | |             +- STARTUOW=-+- 0 -------+----+          |
    | |             |            +- integer -+    |          |
    | |             |                             |          |
    | |             +- STOPUOW=--+- 32767 ---+----+          |
    | |             |            +- integer -+    |          |
    | |             |                             |          |
    | |             +- UOW_REPORT=-+- YES -+------+          |
    | |                            +- NO --+                 |
      +------------------------------------------------------+
    --------------------------------------------------------------
    
    The following description should be added after REPORTDD
    keyword:
    --------------------------------------------------------------
    STARTUOW Keyword
    
     The STARTUOW Keyword is used to specify the number that
     defines the first UOW to be reported in the UOW report
     and the UOW Exception report.
    
     This keyword is optional.
    
     The format of the STARTUOW  keyword is:
      +-------------------------------------------------+
      |>>-- STARTUOW= -+- 0 -------+----------------->< |
      |                +- integer -+                    |
      +-------------------------------------------------+
    
     The variable field is defined as follows:
       integer
         Specify a value from 0 to 32767.
         This value must be less than or equal to the
         value specified for the STOPUOW keyword.
    
     Default: 0
    --------------------------------------------------------------
    STOPUOW Keyword
    
     The STOPUOW keyword is used to specify the number that
     defines the last UOW to be reported in the UOW report and
     the UOW Exception report.
    
     This keyword is optional.
    
     The format of the STOPUOW  keyword is:
      +-------------------------------------------------+
      |>>-- STOPUOW= --+- 32767 ---+----------------->< |
      |                +- integer -+                    |
      +-------------------------------------------------+
    
     The variable field is defined as follows:
       integer
         Specify a value from 0 to 32767.
         This value must be greater than or equal to the
         value specified for the STARTUOW keyword.
    
     Default: 32767
    --------------------------------------------------------------
    UOW_REPORT Keyword
    
     The UOW_REPORT keyword is used to specify whether to generate
     the UOW REPORT.
    
     This keyword is optional.
    
     The format of the UOW_REPORT keyword is:
      +-------------------------------------------------+
      |>>-- UOW_REPORT= -+- YES -+------------------->< |
      |                  +- NO --+                      |
      +-------------------------------------------------+
    
     The variable fields are defined as follows:
          YES
            Generate the UOW REPORT.
          NO
            Do not generate the UOW REPORT.
    
     Default: YES
    ---------------------------------------------------------------
    
    Appendix D. Site default options support
    The following description should be changed as follows:
    --------------------------------------------------------------
    Supported control statement keywords
      All the control statement keywords are available for the
      site default options, except for the AREA keyword, the
      keywords that are associated with the SELECT and OUTPUT
      control statements of ODE, and the keywords that are
    | associated with the THRESHOLD control statement of OPC and
      OER.
    ----------------------------------------------------------------
    
    Appendix G. Messages and codes
      Messages
    The following message should be added as follows:
    --------------------------------------------------------------
    FPX0270E Incorrect UOW range specified: STARTUOW=nnnnn,
    STOPUOW=mmmmm
    
    Explanation: An incorrect UOW range was specified.
    STARTUOW must not be greater than STOPUOW.
    
    System action: Processing ends with a return code of 8.
    
    User response: Correct the keyword value,
    and resubmit the job.
    ----------------------------------------------------------------
    

APAR Information

  • APAR number

    PK61164

  • Reported component name

    IMS HP FP UTILI

  • Reported component ID

    5655K9400

  • Reported release

    320

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-02-15

  • Closed date

    2008-03-11

  • Last modified date

    2008-04-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK34425

Modules/Macros

  •    FPXAQPR0 FPXAQTL0 FPXAQWRK FPXATMDB FPXATMD0
    FPXATO00 FPXATQ00 FPXAUIOB FPXAURC0 FPXAURT0 FPXMSG00 FPXXCPR0
    FPXXCTL0 FPXXCWRK FPXXGMDB FPXXGMD0 FPXXRC00 FPXXRGE0 HFPQFAC0
    H31A320J
    

Publications Referenced
SC18987103    

Fix information

  • Fixed component name

    IMS HP FP UTILI

  • Fixed component ID

    5655K9400

Applicable component levels

  • R320 PSY UK34425

       UP08/03/12 P F803

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89D","label":"IMS HP Fast Path Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
01 April 2008