APAR status
Closed as new function.
Error description
Online Pointer Checker ( OPC ) is being enhanced to suppress specified reports.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Online Pointer Checker and Online * * Expert Reorganization users of High * * Performance Fast Path Utilities FP Online * * Tools Version 3 Release 2 (FMID: H31A320). * **************************************************************** * PROBLEM DESCRIPTION: Fast Path Online Tools (FPO) supports * * UOW REPORT suppression function. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR allows FPO to suppress UOW REPORT or to specify UOW range of the UOW REPORT. This is a FITS requirement MR041207678.
Problem conclusion
Temporary fix
Comments
======================== = DOCUMENTATION CHANGE = ======================== The IMS High Performance Fast Path Utilities for z/OS User's Guide Volume 3: Fast Path Online Tools Version 3 Release 2 (SC18-9871-03). ---------------------------------------------------------------- Chapter 4. Using OPC REPORT statement The following lines should be added as follows: +------------------------------------------------------+ | +-----------------------------+ | | | | | |>>-- REPORT --------------------------------------><- | | | | | | +- REPORTDD=-+- FPXRPTS -+----+ | | | +- ddname --+ | | | | | | | | | +- STARTUOW=-+- 0 -------+----+ | | | | +- integer -+ | | | | | | | | | +- STOPUOW=--+- 32767 ---+----+ | | | | +- integer -+ | | | | | | | | | +- UOW_REPORT=-+- YES -+------+ | | | +- NO --+ | +------------------------------------------------------+ -------------------------------------------------------------- The following description should be added after REPORTDD keyword: -------------------------------------------------------------- STARTUOW Keyword The STARTUOW Keyword is used to specify the number that defines the first UOW to be reported in the UOW report and the UOW Exception report. This keyword is optional. The format of the STARTUOW keyword is: +-------------------------------------------------+ |>>-- STARTUOW= -+- 0 -------+----------------->< | | +- integer -+ | +-------------------------------------------------+ The variable field is defined as follows: integer Specify a value from 0 to 32767. This value must be less than or equal to the value specified for the STOPUOW keyword. Default: 0 -------------------------------------------------------------- STOPUOW Keyword The STOPUOW keyword is used to specify the number that defines the last UOW to be reported in the UOW report and the UOW Exception report. This keyword is optional. The format of the STOPUOW keyword is: +-------------------------------------------------+ |>>-- STOPUOW= --+- 32767 ---+----------------->< | | +- integer -+ | +-------------------------------------------------+ The variable field is defined as follows: integer Specify a value from 0 to 32767. This value must be greater than or equal to the value specified for the STARTUOW keyword. Default: 32767 -------------------------------------------------------------- UOW_REPORT Keyword The UOW_REPORT keyword is used to specify whether to generate the UOW REPORT. This keyword is optional. The format of the UOW_REPORT keyword is: +-------------------------------------------------+ |>>-- UOW_REPORT= -+- YES -+------------------->< | | +- NO --+ | +-------------------------------------------------+ The variable fields are defined as follows: YES Generate the UOW REPORT. NO Do not generate the UOW REPORT. Default: YES --------------------------------------------------------------- Appendix D. Site default options support The following description should be changed as follows: -------------------------------------------------------------- Supported control statement keywords All the control statement keywords are available for the site default options, except for the AREA keyword, the keywords that are associated with the SELECT and OUTPUT control statements of ODE, and the keywords that are | associated with the THRESHOLD control statement of OPC and OER. ---------------------------------------------------------------- Appendix G. Messages and codes Messages The following message should be added as follows: -------------------------------------------------------------- FPX0270E Incorrect UOW range specified: STARTUOW=nnnnn, STOPUOW=mmmmm Explanation: An incorrect UOW range was specified. STARTUOW must not be greater than STOPUOW. System action: Processing ends with a return code of 8. User response: Correct the keyword value, and resubmit the job. ----------------------------------------------------------------
APAR Information
APAR number
PK61164
Reported component name
IMS HP FP UTILI
Reported component ID
5655K9400
Reported release
320
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-02-15
Closed date
2008-03-11
Last modified date
2008-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK34425
Modules/Macros
FPXAQPR0 FPXAQTL0 FPXAQWRK FPXATMDB FPXATMD0 FPXATO00 FPXATQ00 FPXAUIOB FPXAURC0 FPXAURT0 FPXMSG00 FPXXCPR0 FPXXCTL0 FPXXCWRK FPXXGMDB FPXXGMD0 FPXXRC00 FPXXRGE0 HFPQFAC0 H31A320J
| SC18987103 |
Fix information
Fixed component name
IMS HP FP UTILI
Fixed component ID
5655K9400
Applicable component levels
R320 PSY UK34425
UP08/03/12 P F803